Multisite-Based Approach to Assure Inter-Assay System Compatibility among Different Immunoassay Systems through Determining Exchanged Calibrators
نویسندگان
چکیده
It is well known that most immunoassay systems are highly precise but are poor in compatibility of their determinations. Thus, it is difficult to compare the determinations among different systems, posing problems when a patient is transferred to different hospitals or when a laboratory intends to change the system currently used. In the study, we tried to approach how to assure inter-immunoassay compatibility among four different systems through determination of the exchanged calibrators. First, determinations of total protein and albumin, and electrophoretic fractionation demonstrated marked differences among calibrators in their protein constituent. Some calibrators were prepared with human sera, but others were with inorganic or non-human albumin-based solution. Regression analysis of calibrators between the indicated concentrations by manufacturers and those actually determined by the different immunoassay systems revealed that; most slopes were closed to 1.0 for α―fetoprotein and prostate-specific antigen, but widely dissociated from 0.28 to 4.71 for CA19-9. In evaluation of clinical serum samples, determinations by one immunoassay system were compared with those converted based on a linear regression equation that was obtained by determination of the exchanged calibrators. However, this procedure could not improve compatibility, and positive effects of conversion varied by immunoassay systems combined, and also by test parameters. With these, we concluded that simple conversion of determinations by using the exchanged calibrators and a statistical linear regression could not provide us with the expected compatibility. Thus, standardization of target molecules or probes, and of calibrator constituent were urgent issue to assure inter-immunoassay compatibility.
منابع مشابه
ارائه یک مدل احتمالاتی جهت تعیین انسجام متن در سیستم های پرسش و پاسخ تعاملی
Evaluation plays an important role in interactive question answering systems like many computational linguistics fields. The coherence between the questions and the answers exchanged between the user and the system is one of the important criteria in evaluating these systems. In this paper, a new approach to determine the degree of coherence of generated text by the IQA systems is presented. Th...
متن کاملEvaluation of the manual enzyme immunoassay (EMIT) procedure for determination of serum thyroxine.
Our experience with the determination of thyroxine (T4) in serum using a homogeneous enzyme immunoassay technique (EMIT, Syva Corp.) is reported. The intra-assay precision of the EMIT Manual Thyroxine Assay was investigated with 2 different calibrator concentrations and showed coefficients of variation varying from 5--2% for thyroxine concentrations of 40 and 120 micrograms/l thyroxine respecti...
متن کاملA hybrid approach for database intrusion detection at transaction and inter-transaction levels
Nowadays, information plays an important role in organizations. Sensitive information is often stored in databases. Traditional mechanisms such as encryption, access control, and authentication cannot provide a high level of confidence. Therefore, the existence of Intrusion Detection Systems in databases is necessary. In this paper, we propose an intrusion detection system for detecting attacks...
متن کاملRecombinant mouse-human chimeric antibodies as calibrators in immunoassays that measure antibodies to Toxoplasma gondii.
In the present study, we examined the feasibility of using recombinant antibodies containing murine variable regions and human constant regions as calibrators or controls in immunoassays. As a model system, we chose the Abbott IMx Toxo immunoglobulin M (IgM) and Toxo IgG assays designed to detect antibodies to Toxoplasma gondii. Two mouse monoclonal antibodies were selected based on their react...
متن کاملEnzyme conversion immunoassay for determining total homocysteine in plasma or serum.
A rapid and precise immunoassay for quantification of total homocysteine in blood samples is presented. The method avoids the use of radioisotopes and chromatographic separations and relies on enzymatic conversion of homocysteine to S-adenosyl-L-homocysteine, followed by quantification of S-adenosyl-L-homocysteine by an enzyme-linked immunoassay in microtiter format. The within- and between-ass...
متن کامل