Field performance test of an air-cleaner with photocatalysis-plasma synergistic reactors for practical and long-term use.
نویسندگان
چکیده
A practical and long-term usable air-cleaner based on the synergy of photocatalysis and plasma treatments has been developed. A field test of the air-cleaner was carried out in an office smoking room. The results were compared to previously reported laboratory test results. Even after a treatment of 12,000 cigarettes-worth of tobacco smoke, the air-cleaner maintained high-level air-purification activity (98.9% ± 0.1% and 88% ± 1% removal of the total suspended particulate (TSP) and total volatile organic compound (TVOC) concentrations, respectively) at single-pass conditions. Although the removal ratio of TSP concentrations was 98.6% ± 0.2%, the ratio of TVOC concentrations was 43.8% after a treatment of 21,900 cigarettes-worth of tobacco smoke in the field test. These results indicate the importance of suitable maintenance of the reactors in the air-cleaner during field use.
منابع مشابه
Development of a Coil-Shape Photocatalysis-Plasma Synergistic Reactor for a Practical and Long-Term Usable Air-Cleaner
A novel air-cleaner with a coil-shape photocatalysis-plasma synergistic reactor was developed. The air-cleaner showed 95% ± 1% reduction of a TVOCs concentration in tobacco smoke at “single-pass” condition. Air-purification activity of the air-cleaner was stably-maintained after the treatment of 12,000 cigarettes of tobacco smoke.
متن کاملA review of portable air cleaner devices: purification processes, performance standards, effectiveness in controlling indoor air pollutants
Background and objective: Indoor air pollutants are among the five most important environmental health risks. In recent years, concerns regarding indoor air in buildings have increased. In this review, studies conducted on portable air cleaners have been investigated. Materials and methods: After determining the keywords and conducting comprehensive searches in the internet databases, taking i...
متن کاملThe effect of acute restraint stress and dexamethasone on retrieval of long-term memory in rats: an interaction with opiate system
This study investigated whether application of acute restraint stress or dexamethasone, as a glucocorticoid receptor agonist, impaired retrieval of long-term memory and if pretreatment with opiate antagonist naloxone blocked their effects on memory retrieval. Young adult male rats were trained in one trial inhibitory avoidance task (1 mA, 1.5 s foot shock). On retention test given 48 hr after t...
متن کاملThe effect of acute restraint stress and dexamethasone on retrieval of long-term memory in rats: an interaction with opiate system
This study investigated whether application of acute restraint stress or dexamethasone, as a glucocorticoid receptor agonist, impaired retrieval of long-term memory and if pretreatment with opiate antagonist naloxone blocked their effects on memory retrieval. Young adult male rats were trained in one trial inhibitory avoidance task (1 mA, 1.5 s foot shock). On retention test given 48 hr after t...
متن کاملMEASUREMENT AND SIMULATION OF THE INDOOR AIR QUALITY IMPACT OF GASEOUS AIR CLEANERS IN A TEST HOUSE By
Residential and commercial gaseous air cleaning technologies have not gained wide acceptance in the marketplace, in part due to the lack of performance data from field tests or simulation studies. This paper describes a field study of the performance of two gaseous air cleaners in a single room test house and simulations based on these tests with an indoor air quality model (CONTAMW). Air clean...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Molecules
دوره 19 11 شماره
صفحات -
تاریخ انتشار 2014