The cross-sectional shape of the fourfold semitendinosus tendon is oval, not round

نویسندگان

  • Takeshi Oshima
  • Junsuke Nakase
  • Hitoaki Numata
  • Yasushi Takata
  • Hiroyuki Tsuchiya
چکیده

BACKGROUND The looped side of the semitendinosus tendon (ST) graft (i.e., the side inserted into the femoral tunnel during anterior cruciate ligament reconstruction) appears to be oval rather than round. The purpose of this study was to investigate the cross section of the fourfold semitendinosus tendon graft and, more specifically, the differences in pressure exerted by a rounded rectangular tunnel versus a round femoral tunnel. METHODS Seven STs were harvested from cadaveric knees and a fourfold ST graft was made. Aluminum cubes with round or rectangular tunnels containing four-way pressure-sensitive conductive sensors (vertically and bilaterally) were used. The area of both cubes was the same. The graft was inserted into the tunnels 15 mm from the looped edge. After measuring pressure, the graft was fixed using ultraviolet-curing acrylic resin and was cut at 7.5 mm and 15 mm from the lapel edge. The area, axes for the best fitting ellipse of the cross-section, and ellipticity of the axes were measured. RESULTS In the round tunnel, the mean contact pressure was 287.0 ± 136.7 gf at the bilateral sensor; there was no contact pressure detected by the vertical sensor. In the rounded rectangular tunnel, the mean contact pressure was 260.9 ± 186.4 gf at the bilateral sensor and 352.9 ± 49.5 gf at the vertical sensor. Ellipticity was 1.25 ± 0.13 at 7.5 mm, and 1.17 ± 0.07 at 15 mm from the lapel edge of the graft. CONCLUSIONS The cross-sectional shape of the fourfold ST graft was not round, but oval. Moreover, the rounded rectangular tunnel was more fitted to the graft than the round tunnel.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of Magnetic Resonance Imaging to Predict Quadrupled Semitendinosus Graft Diameter in All-Inside Anterior Cruciate Ligament Reconstruction.

This study was conducted to evaluate whether preoperative magnetic resonance imaging (MRI) measurements of the cross-sectional area and length of the semitendinosus tendon correlated with graft diameter. The goal of the study was to identify tendons at risk for requiring graft augmentation. The records of 140 consecutive patients undergoing anterior cruciate ligament (ACL) reconstruction betwee...

متن کامل

Ultrastructure of the chorion and the micropyle of an endemic cyprinid fish, Cyprinion tenuiradius Heckel, 1849 (Teleostei: Cyprinidae) from southern Iran

 The scanning electron microscope was used to investigate the ultrastructures of the egg membrane surface (unfertilized egg) of an endemic cyprinid fish, Cyprinion tenuiradius Heckel, 1849. The eggs of this species were almost circular in shape, had a smooth surface and one type II micropyle consisting of the flat pit and a long canal in the animal polar region. The micropyle region was not fla...

متن کامل

Ultrastructure of the chorion and the micropyle of an endemic cyprinid fish, Cyprinion tenuiradius Heckel, 1849 (Teleostei: Cyprinidae) from southern Iran

 The scanning electron microscope was used to investigate the ultrastructures of the egg membrane surface (unfertilized egg) of an endemic cyprinid fish, Cyprinion tenuiradius Heckel, 1849. The eggs of this species were almost circular in shape, had a smooth surface and one type II micropyle consisting of the flat pit and a long canal in the animal polar region. The micropyle region w...

متن کامل

Bilateral magnetic resonance imaging and functional assessment of the semitendinosus and gracilis tendons a minimum of 6 years after ipsilateral harvest for anterior cruciate ligament reconstruction.

BACKGROUND Previous studies are contradictory in terms of the function, regeneration potential, insertion point, and cross-sectional area of the semitendinosus and gracilis tendons after harvest for anterior cruciate ligament (ACL) reconstruction. HYPOTHESES In the long term, the tendons will regenerate in most patients with a more proximal point of insertion, the cross-sectional area of the ...

متن کامل

Inducement of tissue regeneration of harvested hamstring tendons in a rabbit model

OBJECTIVES The objective of this study was to determine if the use of fascia lata as a tendon regeneration guide (placed into the tendon canal following harvesting the semitendinosus tendon) would improve the incidence of tissue regeneration and prevent fatty degeneration of the semitendinosus muscle. MATERIALS AND METHODS Bilateral semitendinosus tendons were harvested from rabbits using a t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2016