FINAL-FOCUS OPTICS FOR THE LHeC ELECTRON BEAM LINE∗
نویسندگان
چکیده
One of the options considered for the ECFA-CERNNuPECC design study for a Large Hadron electron Collider (LHeC) [1] based on the LHC is adding a recirculating energy-recovery linac tangential to the LHC. First designs of the electron Final Focus System have shown the need to correct the chromatic aberrations. Two designs using different approaches for the chromaticity correction are compared, namely, the local chromaticity correction [2] and the traditional approach using dedicated sections.
منابع مشابه
Probing Anomalous WW γ and WWZ Couplings with Polarized Electron Beam at the LHeC and FCC-Ep Collider
Abstract—We study the anomalous WW and WWZ couplings by calculating total cross sections of two processes at the LHeC with electron beam energy Ee=140 GeV and the proton beam energy Ep=7 TeV, and at the FCC-ep collider with the polarized electron beam energy Ee=80 GeV and the proton beam energy Ep=50 TeV. At the LHeC with electron beam polarization, we obtain the results for the difference of ...
متن کاملAdjustable, short focal length permanent-magnet quadrupole based electron beam final focus system
1098-4402= Advanced high-brightness beam applications such as inverse-Compton scattering (ICS) depend on achieving of ultrasmall spot sizes in high current beams. Modern injectors and compressors enable the production of high-brightness beams having needed short bunch lengths and small emittances. Along with these beam properties comes the need to produce tighter foci, using stronger, shorter f...
متن کاملRadiation protection systems for the final focus test beam at SLAC.
The Final Focus Test Beam (FFTB) is a new beam line at the Stanford Linear Accelerator Center designed to test new beam optics concepts, hardware, and techniques necessary to achieve and measure the small spot sizes required for future generations of high-energy e+e- linear colliders. The FFTB takes a 47 GeVc-1, 1 kW electron beam at the end of the Stanford Linear Accelerator Center linear acce...
متن کاملUsing Beam Orbits
Beam based alignment is being routinely applied in the SLC Final Focus and has proved to be a very useful tool for deEermining the quality of the zeroth order orbit as defined by various beam line elements. Given the stringent requirement on the beam quality at the interaction point (IF’), a well aligned beam line is essential in that it minimizes the confusion which would otherwise arise in th...
متن کاملResults from the Final Focus Test Beam
First experimental results from the Final Focus Test Beam (FFTB) are given in this report. The FFTB has been constructed as a prototype for the final focus system of a future TeV-scale electron-positron linear collider. The vertical dimension of the 47 GeV electron beam from the SLAC linac has been reduced at the focal point of the FFTB by a demagnification of 320 to a beam height of approximat...
متن کامل