MR Diagnosis of a Pulmonary Embolism: Comparison of P792 and Gd-DOTA for First-Pass Perfusion MRI and Contrast-Enhanced 3D MRA in a Rabbit Model
نویسندگان
چکیده
OBJECTIVE To compare P792 (gadomelitol, a rapid clearance blood pool MR contrast agent) with gadolinium-tetraazacyclododecanetetraacetic acid (Gd-DOTA), a standard extracellular agent, for their suitability to diagnose a pulmonary embolism (PE) during a first-pass perfusion MRI and 3D contrast-enhanced (CE) MR angiography (MRA). MATERIALS AND METHODS A perfusion MRI or CE-MRA was performed in a rabbit PE model following the intravenous injection of a single dose of contrast agent. The time course of the pulmonary vascular and parenchymal enhancement was assessed by measuring the signal in the aorta, pulmonary artery, and lung parenchyma as a function of time to determine whether there is a significant difference between the techniques. CE-MRA studies were evaluated by their ability to depict the pulmonary vasculature and following defects between 3 seconds and 15 minutes after a triple dose intravenous injection of the contrast agents. RESULTS The P792 and Gd-DOTA were equivalent in their ability to demonstrate PE as perfusion defects on first pass imaging. The signal from P792 was significantly higher in vasculature than that from Gd-DOTA between the first and the tenth minutes after injection. The results suggest that a CE-MRA PE could be reliably diagnosed up to 15 minutes after injection. CONCLUSION P792 is superior to Gd-DOTA for the MR diagnosis of PE.
منابع مشابه
Dynamic Contrast-Enhanced MRI Using a Macromolecular MR Contrast Agent (P792): Evaluation of Antivascular Drug Effect in a Rabbit VX2 Liver Tumor Model
OBJECTIVE To evaluate the utility of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) using macromolecular contrast agent (P792) for assessment of vascular disrupting drug effect in rabbit VX2 liver tumor models. MATERIALS AND METHODS This study was approved by our Institutional Animal Care and Use Committee. DCE-MRI was performed with 3-T scanner in 13 VX2 liver tumor-bearing r...
متن کاملQuantification of blood-brain-barrier permeability dysregulation and inflammatory activity in MS lesions by dynamic-contrast enhanced MR imaging
Objective: Measurement of blood-brain permeability dysfunction in active and chronic MS lesions with T1-weighted dynamic contrast-enhanced MRI to show variation in inflammatory activity Background: blood-brain-barrier perfusion characterization impaired in MS as some studies have shown recently buta comparison between perfusion parameters in contrast-enhanced and non-enhanced lesions not have ...
متن کاملOptimization of a blood pool contrast agent injection protocol for MR angiography.
PURPOSE To design an ideal first-pass profile for MR angiography (MRA) by optimizing a multiphasic injection protocol based on two experimental animal models. MATERIALS AND METHODS An equivalent contrast-enhanced (CE) MRA injection protocol was developed with controlled injection modalities (injection rate, volume, and dose) in rabbits and pigs. P792, a blood pool contrast agent, was injected...
متن کاملRenal functional contrast-enhanced magnetic resonance imaging: evaluation of a new rapid-clearance blood pool agent (p792) in sprague-dawley rats.
OBJECTIVES The objective of the present study was to compare P792, a new rapid clearance blood pool agent characterized by negligible interstitial diffusion but unrestricted glomerular filtration, with Gd-DOTA in both qualitative and quantitative aspects of renal functional magnetic resonance imaging. MATERIALS AND METHODS Dynamic imaging was performed with a fast T1-weighted gradient-echo se...
متن کاملReproducibility of Magnetic Resonance Perfusion Imaging
Dynamic MR biomarkers (T2*-weighted or susceptibility-based and T1-weighted or relaxivity-enhanced) have been applied to assess tumor perfusion and its response to therapies. A significant challenge in the development of reliable biomarkers is a rigorous assessment and optimization of reproducibility. The purpose of this study was to determine the measurement reproducibility of T1-weighted dyna...
متن کامل