Detection of Amyloid-β42 Using a Waveguide-Coupled Bimetallic Surface Plasmon Resonance Sensor Chip in the Intensity Measurement Mode

نویسندگان

  • Yeon Kyung Lee
  • Kyeong-Seok Lee
  • Won Mok Kim
  • Young-Soo Sohn
چکیده

The waveguide-coupled bimetallic (WcBiM) surface plasmon resonance (SPR) chip had been utilized in the intensity interrogation detection mode to detect amyloid-β42 (Aβ42), a biomarker of the Alzheimer disease. The SPR reflectance curve of the WcBiM chip has the narrower full-width-at-half-maximum (FWHM) compared with the SPR reflectance curve of the conventional gold (Au) chip, resulting in the steeper gradient. For the enhancement of resolution, the light source was fixed at an angle where the slope of the reflectance curve is the steepest, and the change in the reflectance was monitored. For the detection of Aβ42, the antibody of Aβ42 (anti-Aβ42) was immobilized on the WcBiM SPR chip using the self-assembled monolayer. The SPR responses, the average changes in the reflectance to the Aβ42 at the concentrations of 100 pg/ml, 250 pg/ml, 500 pg/ml, 750 pg/ml, 1,000 pg/ml, and 2,000 pg/ml were 0.0111%, 0.0305%, 0.0867%, 0.1712%, 0.3021%, and 0.5577%, respectively, for the three replicates. From linear regression analysis, the calibration curve indicated that the SPR response had a linear relation with Aβ42 with the concentration in the range of 100 pg/ml to 2,000 pg/ml. A control experiment showed the anti-Aβ42-modified surface of the WcBiM chip had a high specificity to Aβ42. Thus, the enhanced resolution by utilizing the WcBiM SPR chip in the intensity interrogation detection mode aids the diagnosis of the Alzheimer disease by detecting the Aβ42 around the criteria concentration (500 pg/ml) without any labeling.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Enhancing performance of a miniaturized surface plasmon resonance sensor in the reflectance detection mode using a waveguide-coupled bimetallic chip

The characteristics of a waveguide-coupled bimetallic (WcBiM) chip in a miniaturized surface plasmon resonance (SPR) sensor and its detection capability for a low molecular weight biomolecule were investigated. The configuration of the WcBiM chip was gold (Au)/waveguide (ZnS-SiO2)/silver (Ag). In the intensity measurement mode, the sensitivity could be improved by reducing the full width at hal...

متن کامل

Optimization of Sensitivity and Stability of Gold/Silver bi-Layer Thin Films Used in Surface Plasmon Resonance Chips

The aim of this study is experimental assay of sensitivity and stability of a bimetallic silver/gold SPR sensor chip. This chip utilizes the sensitivity of the silver and the stability of the gold. Moreover, the Silver layer (instead of usual Cr or Ti layer) was used as an adhesive intermediate layer between the Gold layer and the glass substrate. The optimization of the Gold/Silver thickness u...

متن کامل

Resolution Enhancement in Surface Plasmon Resonance Sensor Based on Waveguide Coupled Mode by Combining a Bimetallic Approach

In this study, we present and demonstrate a new route to a great enhancement in resolution of surface plasmon resonance sensors. Basically, our approach combines a waveguide coupled plasmonic mode and a kind of Au/Ag bimetallic enhancement concept. Theoretical modeling was carried out by solving Fresnel equations for the multilayer stack of prism/Ag inner-metal layer/dielectric waveguide/Au out...

متن کامل

Design of a High-Performance Micro Integrated Surface Plasmon Resonance Sensor Based on Silicon-On-Insulator Rib Waveguide Array

Based on silicon-on-insulator (SOI) rib waveguide with large cross-section, a micro integrated surface plasmon resonance (SPR) biochemical sensor platform is proposed. SPR is excited at the deeply etched facet of the bend waveguide by the guiding mode and a bimetallic configuration is employed. With the advantages of SOI rib waveguide and the silicon microfabrication technology, an array of the...

متن کامل

Fabrication and Characterization of the Fiber Optical Taper for a Surface Plasmon Resonance Sensor

For a fiber optical surface plasmon resonance (SPR) sensor a short part of its cladding should be removed to coat a thin layer of a metal. Usually this is problematic when an optical fiber with small core diameter is used. In this paper, a new method using µliter droplet of the HF acid for short fiber optical taper fabrication is reported. Using this method in a multi-mode optical fiber w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014