A monitoring and physiological control system for determining aortic valve closing with a ventricular assist device.

نویسندگان

  • So-Hyun Jansen-Park
  • Sotirios Spiliopoulos
  • Hongyu Deng
  • Nick Greatrex
  • Ulrich Steinseifer
  • Dilek Guersoy
  • Reiner Koerfer
  • Gero Tenderich
چکیده

OBJECTIVES Real-time monitoring of the aortic valve function and the loading state of the left ventricle (LV) during mechanical circulatory support is essential. Therefore, we developed a system that determines accurately the aortic valve closing moment based on integrals derived from the pump inlet pressure and the pump power [pressure-power area (PPA)]. METHODS A Deltastream diagonal pump was implanted in 10 healthy Rhoen sheep. Changes in ventricular volume and pressure in different assist levels were measured by a conductance catheter placed in the LV and were correlated with intrinsic pump signals, motor power, voltage and current. Measurements were obtained in the state of normal as well as decreased left ventricular contractility induced by β-blockers. RESULTS Complete datasets were obtained in seven animals. The PPA-feedback signal reached its maximum at the speed of aortic valve closing. This was validated by pressure-volume (PV)-catheter measurements both at the baseline and in the state of decreased contractility. In both cases, zero-crossing occurred at the point of aortic valve closing speed. CONCLUSIONS With this trial, we deliver the experimental basis for the development of an automatic feedback controller that would allow periodic speed changes in accordance with the loading state of the native ventricle and the opening state of the aortic valve. This would deliver real-time data to treating physicians and enable the establishment of a standard weaning protocol.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)

Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...

متن کامل

Control Method of a Rotary Blood Pump for a Left Ventricular Assist Device

The aim of the investigation is to develop a control method of a rotary blood pump (RBP) to solve the following problems: estimation of the pump flow rate, achievement and maintaining of the desired flow level through the continuous adjustment of pump speed and prevention of adverse effects on the cardiovascular system. Results. Functional chart of RBP control consists of several units: a unit ...

متن کامل

Improvement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization

In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...

متن کامل

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

High-risk Coronary Artery Bypass Grafting and Mitral Valve Replacement in a HIV Positive Patient

Certain subsets of high-risk mitral valve patients are not suitable candidates for transcatheter therapies. The objective of this report is to present a young patient with combined mitral valve and coronary artery disease to illustrate these challenges.In this report, we present a 47-year-old man with longstanding HIV infection who was referred with severe mitral regurgitation (MR) and profound...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 46 3  شماره 

صفحات  -

تاریخ انتشار 2014