The b matrix in diffusion tensor echo-planar imaging.

نویسندگان

  • J Mattiello
  • P J Basser
  • D Le Bihan
چکیده

In diffusion tensor imaging (DTI) an effective diffusion tensor in each voxel is measured by using a set of diffusion-weighted images (DWIs) in which diffusion gradients are applied in a multiplicity of oblique directions. However, to estimate the diffusion tensor accurately, one must account for the effects of all imaging and diffusion gradient pulses on each signal echo, which are embodied in the b matrix. For DTI to be practical clinically, one must also acquire DWIs rapidly and free of motion artifacts, which is now possible with diffusion-weighted echo-planar imaging (DW-EPI). An analytical expression for the b matrix of a general DW-EPI pulse sequence is presented and then validated experimentally by measuring the diffusion tensor in an isotropic phantom whose diffusivity is already known. The b matrix is written in a convenient tabular form as a sum of individual pair-wise contributions arising from gradient pulses applied along parallel and perpendicular directions. While the contributions from readout and phase-encode gradient pulse trains are predicted to have a negligible effect on the echo, the contributions from other imaging and diffusion gradient pulses applied in both parallel and orthogonal directions are shown to be significant in our sequence. In general, one must understand and account for the multiplicity of interactions between gradient pulses and the echo signal to ensure that diffusion tensor imaging is quantitative.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analytical Calculation of the Matrix in Diffusion Imaging

The clinical ability to measure molecular diffusion non­ invasively and in vivo using magnetic resonance imag­ ing (MRI) has generated great interest (1). In tissues, the effective diffusivity depends upon tissue anatomy, microstructure, and gradient pulse parameters. Diffu­ sion MR spectroscopy (2-4), 2DFT spin-echo imaging (5-7), and echo-planar imaging (EPI) (8-11), of in vivo isotropic medi...

متن کامل

Diffusion-tensor MR imaging of the human brain with gradient- and spin-echo readout: technical note.

Diffusion-tensor MR imaging of the brain is an objective method that can measure diffusion of water in tissue noninvasively. Five adult volunteers participated in this study that was performed to evaluate the potential of gradient- and spin-echo readout for diffusion-tensor imaging by comparing it with single-shot spin-echo echo-planar imaging. Gradient- and spin-echo readout provides comparabl...

متن کامل

b matrix errors in echo planar diffusion tensor imaging

Diffusion-weighted magnetic resonance imaging (DW-MRI) is a recognized tool for early detection of infarction of the human brain. DW-MRI uses the signal loss associated with the random thermal motion of water molecules in the presence of magnetic field gradients to derive parameters that reflect the translational mobility of the water molecules in tissues. If diffusion-weighted images with diff...

متن کامل

Comparison of Single-Shot Echo-Planar and Line Scan Protocols for Diffusion Tensor Imaging1

Rationale and Objectives. Both single-shot diffusion-weighted echo-planar imaging (EPI) and line scan diffusion imaging (LSDI) can be used to obtain magnetic resonance diffusion tensor data and to calculate directionally invariant diffusion anisotropy indices, ie, indirect measures of the organization and coherence of white matter fibers in the brain. To date, there has been no comparison of EP...

متن کامل

Diffusion tensor echo planar imaging of mouse brain after brief focal middle cerebral artery occlusion at 14T

Figure 2 ADC map at 8h (a), T2WI image at 24h (c) of one mouse and MR spectra at 8 (c) and 24h (d). The spectra (SPECIAL, TE/TR=2.8/4000ms, NT=360) (5) was acquired from abnormal ADC region (yellow square, 1.4×1.2×1.6mm) at 8h (b) and T2-hyper-intensive regions (red square, 1.4×1.2×1.6mm) at 24h (d), and displayed with Gaussian adoptization (gf=0.15s). Diffusion tensor echo planar imaging of mo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 37 2  شماره 

صفحات  -

تاریخ انتشار 1997