Simultaneous Measurement of Changing Intraocular Pressure and Outflow Facility in the Vervet Monkey by Constant Pressure Infusion.
نویسنده
چکیده
The sources of error and the optivial design of an anterior chamber infusion method for the study of rapid changes in outflow facility and intraocular pressure are discussed, with a series of definite recommendations. A saline solution for anterior chamber infusion that preserves the outflow resistance of the monkey eye has been described. Data are given showing the degree of uncertainty, caused by random factors, of measurements of outflow facility and intraocular pressure with the two-level constant pressure infusion method.
منابع مشابه
Topical epinephrine effects on true outflow resistance and pseudofacility in vervet monkeys studied by a new anterior chamber perfusion technique.
Outflow facility was measured in 20 anesthetized vervet monkeys by two techniques; both involved the recording of the rate of inflow of fluid from a reservoir connected to the anterior chamber. In the flrst technique the pressure in the anterior chamber was periodically raised and lowered, while the extraocular venous pressure was not changed. In the second technique the intraocular pressure wa...
متن کاملAdenosine 3',5'-monophosphate analogue increases the outflow facility of the primate eye.
Our previous studies showed that cyclic-AMP increases the outflow facility of the eye of the rabbit. In this investigation, an analogue of cyclic-AMP, the 8-methylthio derivative, perfused into the anterior chamber of the eye of the vervet monkey, increased outflow facility twofold. This observation supports the hypothesis that cyclic-AMP mediates the action of adrenergic agents to reduce intra...
متن کاملThe effect of miotics on the intraocular pressure of conscious owl monkeys
1. Nissen, O. I., and Hoppe, R.: The facility of aqueous outflow calculated from the rate of fall in applanation pressure after intravenous acetazolamide in man, Acta Ophthalmol. 52: 390, 1974. 2. Nissen, O. I.: The immediate response in applanation pressure to intravenous acetazolamide in primary glaucomas and glaucoma suspects, Acta Ophthalmol. 53: 537, 1975. 3. Grant, W. M.: Tonographic meth...
متن کاملThe measurement of pseudofacility and true facility by constant pressure perfusion in the normal rhesus monkey eye.
Facility of bulk aqueous humor outflow via conventional channels, true facility, and pressure sensitive suppression of aqueous humor inflow, pseudofacility, were measured by constant pressure perfusion in 24 eyes of 12 rhesus monkeys. True facility was found to have a mean value of 0.55 ,uL minr mm. Hg~ and pseudofacility was found to have a mean value of 0.12 p.L minr mm. Hg-. This figure is i...
متن کاملInfluence of intraocular pressure on aqueous outflow facility in enucleated eyes of different mammals.
Freshly enucleated monkey, calf, and human eyes were quantitatively perfused with mock aqueous humor through the anterior chamber by a constant pressure technique. After baseline perfusion at 15 mm Hg, intraocular pressure was raised to 45 mm Hg and later reduced back to 15 mm Hg. Calf and human (both adult and infant) eyes had lower outflow facilities at 45 than at 15 mm Hg. However, four type...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology
دوره 3 شماره
صفحات -
تاریخ انتشار 1964