Dynamic variations in the ultrasound greyscale median of carotid artery plaques
نویسندگان
چکیده
BACKGROUND Several studies have found that the ultrasound greyscale median (GSM) of carotid artery plaques may be useful for predicting the risk of cerebrovascular events. However, measurements of GSM are typically performed on still ultrasound images ignoring any variations that may be observed on a frame-by-frame basis. The aim of this study was to establish the existence and investigate the nature and extent of these variations. METHODS Employing a novel method that enabled plaque boundaries to be tracked semi-automatically, variations in the plaque GSM and observed cross-sectional area were measured for 27 carotid artery plaques (19 consecutive patients, stenosis range 10%-80%) over image sequences of up to 10 seconds in length acquired with a mean frame rate of 32 frames per second. RESULTS Our results showed a mean inter-frame coefficient of variation (CV) of 5.2% (s.d. 2.5%) for GSM and 4.2% (s.d. 2.9%) for the plaque area. Thirteen of the 27 plaques (48%) exhibited CV in GSM greater than 5% whereas only six plaques (22%) had CV in plaque area of greater than 5%. There was no significant correlation between the CV of GSM and plaque area. CONCLUSIONS Inter-frame variations in the plaque GSM such as those found in this study have implications on the reproducibility of GSM measurements and their clinical utility. Studies assessing the GSM of carotid artery plaques should consider these variations.
منابع مشابه
Wall motion in the stenotic carotid artery: association with greyscale plaque characteristics, the degree of stenosis and cerebrovascular symptoms
BACKGROUND Systolic dilation of the atherosclerotic carotid artery depends on several factors including arterial compliance and the haemodynamic environment. The purpose of this study was to quantify wall motion in stenotic carotid arteries and investigate any associations with the ultrasound greyscale plaque characteristics, the degree of stenosis, and the presence of cerebrovascular symptoms....
متن کاملAutomatic measurement of instantaneous changes in the walls of carotid artery with sequential ultrasound images
Introduction: This study presents a computerized analyzing method for detection of instantaneous changes of far and near walls of the common carotid artery in sequential ultrasound images by applying the maximum gradient algorithm. Maximum gradient was modified and some characteristics were added from the dynamic programming algorithm for our applications. Methods: The algorithm was evaluat...
متن کاملCarotid doppler ultrasound evaluation in patients with lichen planus
Background: Lichen planus is a chronic inflammatory disease associated with an increased risk of subclinical atherosclerosis and cardiovascular diseases. This study aimed to evaluate patients with lichen planus using carotid Doppler ultrasound parameters.Methods: Forty patients with lichen planus and 40 controls were included in this study. Common carotid...
متن کاملShear wave elastography imaging of carotid plaques: feasible, reproducible and of clinical potential
BACKGROUND Shear Wave Elastography (SWE) imaging is a novel ultrasound technique for quantifying tissue elasticity. Studies have demonstrated that SWE is able to differentiate between diseased and normal tissue in a wide range clinical applications. However its applicability to atherosclerotic carotid disease has not been established. The aim of this study was to assess the feasibility and pote...
متن کاملCharacterization of Carotid Artery Plaques Using Real-time Compound B-mode Ultrasound
Background and Purpose—Real-time compound ultrasound imaging is a new technique for improving the image quality of B-mode scanning. We investigated the value of this method for the characterization of atherosclerotic plaques in the internal carotid artery. Methods—Thirty-two patients (22 men, 10 women; mean age, 75 years) with plaques of the internal carotid artery as identified by high-resolut...
متن کامل