Biocompatibility of poly2methoxyethylacrylate coating for cardiopulmonary bypass.

نویسندگان

  • Manabu Noguchi
  • Kiyoyuki Eishi
  • Seiichi Tada
  • Shiro Yamachika
  • Shiro Hazama
  • Kenta Izumi
  • Kazuyoshi Tanigawa
چکیده

The systemic inflammatory response to cardiopulmonary bypass (CPB) may contribute to the development of postoperative complications. Heparin-coated circuits and poly2methoxyethylacrylate (PMEA)-coated circuits have been developed to reduce the risk of such complications. We compared the biocompatibility of these circuits. Twelve patients scheduled to undergo elective coronary artery bypass grafting (CABG) with CPB were assigned to CPB with a PMEA-coated circuit (PMEA-coated group, n=6) or a heparin-coated circuit (heparin-coated group, n=6). The plasma concentrations of the following inflammatory markers were measured before CPB and just after, 4 hours after, and 24 hours after the termination of CPB: cytokines (interleukin [IL]-6, IL-8, IL-10), complement factor (C3a), polymorphonuclear elastase (PMNE), and coagulofibrinolytic factors (thrombin-antithrombin III complex [TAT], D-dimer). Postoperative clinical response was evaluated on the basis of respiratory index, blood loss, and the postoperative and preoperative body-weight percent ratio. There were no significant differences between the groups in the plasma concentrations of IL-6, IL-10, C3a, PMNE, TAT, or D-dimer. Plasma IL-8 concentrations were below the assay detection limits at all time points in both groups. Clinical variables did not differ significantly between the groups. In conclusion, PMEA-coated CPB circuits are as biocompatible as heparin-coated CPB circuits and prevent postoperative organ dysfunction in patients undergoing elective CABG with CPB.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Management of Heparin-Resistant Patients with Benefits? Maximizing Biocompatibility in Cardiopulmonary Bypass: Combining ATryn® Recombinant Antithrombin III and Carmeda® Heparin-Bonded Perfusion Circuits: A Case Series.

As many as 25% of our cardiopulmonary bypass (CPB) patients have a diminished heparin response and fail to reach a therapeutic activated clotting time (ACT). We treat a majority of these patients with antithrombin III (ATryn®, recombinant antithrombin III [rhAT], rEVO Biologics). Our current CPB circuit uses Medtronic Carmeda® coating. We observed less post-operative bleeding in a number of pat...

متن کامل

Phosphorylcholine coating of bypass systems used for young infants does not attenuate the inflammatory response.

BACKGROUND Contact of blood with the artificial surfaces of the cardiopulmonary bypass (CPB) system is considered to be a main cause of complement activation. Improving the biocompatibility of the system by reduction of contact activation of blood elements and thereby producing less inflammatory response is evidently desired, especially for neonates and infants who are more susceptible to the d...

متن کامل

Is using an open-reservoir cardiopulmonary bypass circuit after 6 days on standby safe?

OBJECTIVES To investigate the sterility and biocompatibility of a stored open-reservoir cardiopulmonary bypass circuit maintained on standby. METHODS A total of four cardiopulmonary bypass circuits were assembled, primed and left to recirculate. One unit was placed in a positive-pressure operating room and the other three were placed in the intensive care unit. The primed solutions, which emp...

متن کامل

Inflammatory response after coronary revascularization: off-pump versus on-pump (heparin-coated circuits and poly2methoxyethylacrylate-coated circuits).

OBJECTIVE Off-pump coronary artery bypass grafting (OPCAB) may reduce the inflammatory response associated with cardiopulmonary bypass (CPB) and contribute to minimizing postoperative complications. Heparin-coated circuits and poly2methoxyethylacrylate (PMEA)-coated circuits were developed to reduce such complications. We compared the postoperative inflammatory response with or without CPB. M...

متن کامل

Quantitative evaluation of heparin-coated versus non-heparin-coated bypass circuits during cardiopulmonary bypass.

The extracorporealization of blood activates various elements of the fibrinolytic, coagulation, and complement systems. It is theorized that advancements in biocompatibility ameliorate many of the changes leading to improved patient management. The purpose of this study was to determine if heparin-coated circuit (HCC) utilization during cardiopulmonary bypass enhances patient outcomes in a cost...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia

دوره 9 1  شماره 

صفحات  -