We present a new technique for the correction of optical aberrations in wide-field fluorescence microscopy. Segmented-Pupil Image Interferometry (SPII) uses a liquid crystal spatial light modulator placed in the microscope's pupil plane to split the wavefront originating from a fluorescent object into an array of individual beams. Distortion of the wavefront arising from either system or sample aberrations results in displacement of the images formed from the individual pupil segments. Analysis of image registration allows for the local tilt in the wavefront at each segment to be corrected with respect to a central reference. A second correction step optimizes the image intensity by adjusting the relative phase of each pupil segment through image interferometry. This ensures that constructive interference between all segments is achieved at the image plane. Improvements in image quality are observed when Segmented-Pupil Image Interferometry is applied to correct aberrations arising from the microscope's optical path.
منابع مشابه
Reducing depth induced spherical aberration in 3D widefield fluorescence microscopy by wavefront coding using the SQUBIC phase mask
Imaging thick biological samples introduces spherical aberration (SA) due to refractive index (RI) mismatch between specimen and imaging lens immersion medium. SA increases with the increase of either depth or RI mismatch. Therefore, it is difficult to find a static compensator for SA. Different wavefront coding methods have been studied to find an optimal way of static wavefront correction to ...
متن کاملPhase-retrieved pupil functions in wide-field fluorescence microscopy.
Pupil functions are compact and modifiable descriptions of the three-dimensional (3D) imaging properties of wide-field optical systems. The pupil function of a microscope can be computationally estimated from the measured point spread function (PSF) using phase retrieval algorithms. The compaction of a 3D PSF into a 2D pupil function suppresses artefacts and measurement noise without resorting ...
متن کاملMichelson wide-field stellar interferometry: principles and experimental verification.
A new interferometric technique for Michelson wide-field interferometry is presented that consists of a Michelson pupil-plane combination scheme in which a wide field of view can be achieved in one shot. This technique uses a stair-shaped mirror in the intermediate image plane of each telescope in the array, allowing for simultaneous correction of the differential delay for the on-axis and off-...
متن کاملWide field-of-view fluorescence image deconvolution with aberration-estimation from Fourier ptychography.
This paper presents a method to simultaneously acquire an aberration-corrected, wide field-of-view fluorescence image and a high-resolution coherent bright-field image using a computational microscopy method. First, the procedure applies Fourier ptychographic microscopy (FPM) to retrieve the amplitude and phase of a sample, at a resolution that significantly exceeds the cutoff spatial frequency...
متن کاملSpatial Light Modulation as a Versatile Tool for Sensorless Aberration Correction in Fluorescence Microscopy and Nanoscopy
Spatial (phase-only) light modulators (SLMs) have successfully been used for different tasks in microscopy, one prominent example being the doughnut beam shaping in STED nanoscopy [1]. Once implemented into the laser beam path of a microscopic imaging system, its free programmability makes the SLM a versatile instrument for multiple uses. Aberration correction in such a retrofitted system, for ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics express
دوره 20 13 شماره
صفحات -
تاریخ انتشار 2012