A comparison of supraglottic airway i-gel™ vs. classic laryngeal mask airway in small children
نویسندگان
چکیده
BACKGROUND i-gel™ is a new single-use supraglottic airway device without an inflatable cuff. This study was designed to compare the usefulness of i-gel™ versus a classic laryngeal mask airway (cLMA) in small children. METHODS Sixty-three children (age range : 4-72 months) were randomly assigned to an i-gel™ or cLMA group. We evaluated hemodynamic data, airway sealing ability, the success rate of insertion, and adverse events including an inadvertent sliding out during ventilation. RESULTS Demographic data and hemodynamic data obtained immediately after the insertion of these devices did not differ between the two groups. The success rates for insertion on the first attempt were 77 and 84% for i-gel™ and cLMA, respectively (P = 0.54), and the overall success rates were 87 and 100% respectively (P = 0.14). There were no significant differences in terms of airway leak pressure. The inserted i-gel™ inadvertently slid out in 8 of 31 patients but only one sliding out case occurred in the cLMA group (P = 0.02). There were no differences between the groups in terms of other side effects (e.g., coughing, bleeding) associated with the use of i-gel™ and cLMA (P = 0.75 and 0.49, respectively). CONCLUSIONS Oropharyngeal leak pressure and insertion success rate of i-gel™ are similar to those of cLMA. However, i-gel™ is prone to inadvertent sliding out of the mouth in small children. Therefore, it is recommended that the i-gel™ should be secured more tightly to avoid displacement of the device.
منابع مشابه
Comparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries
Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...
متن کاملComparison of the i-gel™ and the Laryngeal Mask Airway Classic™ in terms of clinical performance.
PURPOSE The i-gel™ is one of the second generation supraglottic airway devices. Our study was designed to compare the i-gel and the Laryngeal Mask Airway Classic™ with respect to the clinical performance. METHODS We compared the performance of the i-gel with that of the Laryngeal Mask Airway Classic in 120 patients undergoing urologic surgery during general anesthesia without muscle relaxant ...
متن کاملComparison between i-gel airway an the proseal laryngeal mask airway in pediatric patients undergoing general anesthesia
Background The I-gel airway is a new supraglottic airway device without an inflatable cuff. In this study we compare the efficacy of the I-gel airway with the Proseal laryngeal mask airway (p-LMA) in children undergoing elective surgery under general anesthesia without use of muscle relaxants. Methods Eighty children, one to twelve years of age posted for elective surgery under general anesthes...
متن کاملA Comparison of Three Different Supraglottic Airway Devices in Neonatal Airway Training during Resuscitation Simulation
Objective: The aim of this study was to compare the success rates for insertion using the laryngeal mask, laryngeal tube, and I-gel supraglottic airway devices in a neonatal airway manikin during a resuscitation simulation course. Methods: Three groups of health care professionals were given a brief supervised training in using the devices. For each participant the positioning of each device wa...
متن کاملA randomized equivalence trial comparing the i-gel and laryngeal mask airway Supreme in children.
BACKGROUND The laryngeal mask airway Supreme (Supreme) is a new single-use supraglottic device with gastric access capability now available in all sizes for children. OBJECTIVES To compare the i-gel with the Supreme in children for routine airway maintenance. MATERIALS/METHODS One hundred and seventy children, aged 3 months to 11 years, 5-50 kg in weight, were randomly assigned to receive e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 66 شماره
صفحات -