Planning and Dosimetric Comparisons of IMRT Lung Cancers with Three Advanced Optimization Algorithms

نویسندگان

  • Yie Chen
  • Jie Qu
  • Jack Yang
  • Mitch Weiss
  • Sang Sim
  • Xiongfei Liao
چکیده

Purpose: To evaluate planning quality and dosimetric differences of clinically deliverable Intensity-modulated Radiation Therapy lung plans generated from Tomotherapy, Pinnacle, and RayStationTM treatment planning systems. Method and Materials: Ten patients diagnosed with non-small-cell lung carcinoma (NSCLC) previously treated with plans on Pinnacle using Direct Machine Parameter Optimization were randomly selected and re-planned with Tomotherapy dose volume constraints and same beam geometry with RayStation Multi Criteria Optimization (MCO) equivalent uniform dose (EUD) or dose volume constraints, respectively. Prescription was established as 60 Gy to cover > 95% of PTV. Planning outcomes such as D95 (95% of volume of PTV receiving the prescribed dose), D5, D33, mean heart and lung doses, V20 (volume of lung receiving 20 Gy), and max cord dose of 1cm were evaluated according to our departmental clinical protocols. Conformity index (CI = PTV/prescription isodose volume) and homogeneity index (HI = D5/D95) were also reported simultaneously. All plans were successfully uploaded for delivery verification. Results: Mean volume of calculated PTV was 356 ± 141 cm. The planning results indicated that CI, HI, D95 and D5 of PTV, V20 of lung, and 1cm max cord dose were comparable but with better overall dosimetric distributions with conformity and homogeneity index from Tomotherapy plans in comparison to both Pinnacle and RayStation planning outcomes. Conclusions: Tomotherapy plans achieved better uniform tumor coverage with fewer hot spots while sparing more critical structures with superior dose fall-off. RayStation plans with MCO automatically generated a set of Pareto optimized solutions with given objectives to allow tradeoffs between targets and critical organs and tended to achieve better tumor coverage compared to Pinnacle. All three planning algorithms can generate clinical deliverable IMRT lung plans while Tomotherapy plans provide superior dosimetric indexes compared to Pinnacle and RayStation due to its unique beamlet optimization process with high modulation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric comparison between intensity modulated radiotherapy and three dimensional conformal radiotherapy planning in patients with locally advanced cervical carcinoma

Background: External beam radiotherapy (EBRT) is mainstay of treatment in patients with locally advanced cervical carcinoma (LACC). Three dimensional conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT) are mainly used in EBRT. However which one is superior is still controversial. Materials and Methods: Forty patients of LACC treated with IMRT were selected for this study....

متن کامل

Dosimetric comparisons of VMAT, IMRT and 3DCRT for locally advanced rectal cancer with simultaneous integrated boost

PURPOSE The purpose of this study is to compare the dosimetric differences among volumetric modulated arc therapy (VMAT), fixed-field intensity modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) for the preoperative locally advanced rectal cancer (LARC). METHODS Ten LARC patients treated in our department using the simultaneous escalate strategy were retrospec...

متن کامل

Comparison of dosimetric radiotherapy of whole left- breast cancer using conventional tangential wedge-based techniques (CTT) and three intensity modulation techniques (IMRT)

Introduction: Whole breast radiotherapy after breast-conserving surgery decrease the risk of local recurrence. this study investigates the dosimetric aspects of intensity modulated radiotherapy (IMRT) compared to conventional tangential wedge-based beams techniques (CTT) of the whole breast in early stages breast cancer patients.   Materials and Methods: Co...

متن کامل

Dosimetric Evaluation of Dose calculation algorithms of Monaco Treatment Planning System in the heterogeneities area

Introduction: In radiation therapy, the accuracy of dose calculations by a treatment planning system (TPS) is important to achieve tumor control and to spare normal tissue. Treatment planning system calculations in the heterogeneous situation may present significant inaccuracies. In this study, three different dose calculation algorithms, pencil beam (PB), collapsed cone (CC), ...

متن کامل

Dosimetric advantages of intensity modulated radiation therapy in locally advanced lung cancer

PURPOSE Radiation therapy plays an essential role in the treatment of locally advanced lung cancer, but it inevitably leads to incidental and unnecessary dose to critical organs, including the lung, heart, and esophagus. Numerous radiation dose-volumetric parameters have been associated with increased risk of morbidity and mortality. The purpose of the present study is to quantify differences i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013