Evaluation of the Method of Hemostasis after Femoral Arterial Puncture

نویسندگان

  • Jae-Hwan Cho
  • Hae-Kag Lee
چکیده

[Purpose] This study assessed the advantages and shortcomings of methods for hemostasis in patients who had received angiography after femoral arterial puncture using manual, compression device, or a combination of manual compression and a compression device. In addition, the success rates, complications, etc, were analyzed. [Subjects and Methods] One hundred and eighty patients who had undergone angiography after femoral arterial puncture were divided into three groups according to the method of hemostasis. For group A, immediately after angiography, an Angio-Seal device was placed in the puncture area and compressed using a compression device. For group B, after angiography, the puncture area was compressed with the hands directly. For group C, the puncture area was compressed using a compression device for approximately 10 min, and the puncture area was then compressed with the hands. In each group, the following correlations were analyzed: the time to hemostasis after angiography and gender, the time to hemostasis of each generation and the hemoglobin value, and platelet value and the time to hemostasis. [Results] The results showed a similar time to hemostasis regardless of gender or generation. The correlation between the hemoglobin value, platelet value, and the time to hemostasis were not significant. Group A showed the shortest mean time to hemostasis of the three groups (20.37 ± 8.23 min). No complications caused by the hemostasis method were detected in group B. Group A showed the highest incidence of complications caused by hemostasis. [Conclusion] Overall, hemostasis performed mutually is safe and effective for patients according to their condition.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تأثیر راه‌اندازی زودرس بیماران بر میزان خونریزی و هماتوم پس از آنژیوگرافی از طریق شریان فمورال در بخش پست آنژیوگرفی مرکز آموزشی و درمانی آیت‌اله موسوی زنجان 1389

Introduction: Coronary angiography is frequently applied for diagnostic purposes in patient with coronary artery disease. There is no consensus about the optimal time for the ambulation on patients following femoral arterial puncture. This study intended to investigate the differences between 6 hours of complete bed rest and 2 hours of complete bed rest for the patients after angiography. Met...

متن کامل

Effectiveness of mechanical compression devices in attaining hemostasis after femoral sheath removal.

BACKGROUND Cardiac interventions are widely accepted as a practical treatment option for coronary artery disease. However, few changes have occurred in the techniques used for percutaneous arterial cannulation and for attaining hemostasis after cardiac interventions. To date, researchers have focused on techniques to achieve optimal hemostasis at the time of removal of the arterial catheter and...

متن کامل

False Aneurysm of the Common Femoral Artery in an Infant after a Phlebotomy

False Aneurysms are uncommon in the pediatric population. We report a case of false aneurysm of the common femoral artery (CFA) after accidental arterial puncture, during a phlebotomy for blood sample. The lesion was surgically resected and arterial continuity restored by end to end anastomosis. The postoperative course was uneventful.

متن کامل

Starclose SE® hemostasis after 6F direct antegrade superficial femoral artery access distal to the femoral head for peripheral endovascular procedures in obese patients.

PURPOSE Direct superficial femoral artery (SFA) antegrade puncture is a valid alternative to common femoral artery (CFA) access for peripheral vascular interventions. Data investigating vascular closure device (VCD) hemostasis of distant SFA 6F access are limited. We aimed to investigate the safety and effectiveness of the Starclose SE® VCD for hemostasis, following direct 6F antegrade SFA acce...

متن کامل

Determination of efficacy of a novel alginate dressing in a lethal arterial injury model in swine.

INTRODUCTION Alginate is a biocompatible polysaccharide that is commonly used in the pharmaceutical, biomedical, cosmetic, and food industries. Though solid dressings composed of alginate can absorb water and promote wound healing, they are not effective hemostatic materials, particularly against massive hemorrhage. The purpose of this study is to attempt to increase the hemostatic capabilities...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 26  شماره 

صفحات  -

تاریخ انتشار 2014