Stereoscopic vision display technology in real-time three-dimensional echocardiography-guided intracardiac beating-heart surgery.

نویسندگان

  • Nikolay V Vasilyev
  • Paul M Novotny
  • Joseph F Martinez
  • Hugo Loyola
  • Ivan S Salgo
  • Robert D Howe
  • Pedro J del Nido
چکیده

OBJECTIVE Stereoscopic vision display technology has been shown to be a useful tool in image-guided surgical interventions. However, the concept has not been applied to 3-dimensional echocardiography-guided cardiac procedures. We evaluated stereoscopic vision display as an aid for intracardiac navigation during 3-dimensional echocardiography-guided beating-heart surgery in a model of atrial septal defect closure. METHODS An atrial septal defect (6 mm) was created in 6 pigs using 3-dimensional echocardiography guidance. The defect was then closed using a catheter-based patch delivery system, and the patch was attached with tissue mini-anchors. Stereoscopic vision was generated with a high-performance volume renderer with stereoscopic glasses. Three-dimensional echocardiography with stereoscopic vision display was compared with 3-dimensional echocardiography with standard display for guidance of surgical repair. Task performance measures for each anchor placement (N = 32 per group) were completion time, trajectory of the tip of the anchor deployment device, and accuracy of the anchor placement. RESULTS The mean time of the anchor deployment for stereoscopic vision display group was shorter by 44% compared with the standard display group: 9.7 +/- 0.9 seconds versus 17.2 +/- 0.9 seconds (P < .001). Trajectory tracking of the anchor deployment device tip demonstrated greater navigational accuracy measured by trajectory deviation: 3.8 +/- 0.7 mm versus 6.1 +/- 0.3 mm, 38% improvement (P < .01). Accuracy of anchor placement was not significantly different: 2.3 +/- 0.3 mm for the stereoscopic vision display group versus 2.3 +/- 0.3 mm for the standard display group. CONCLUSION Stereoscopic vision display combined with 3-dimensional echocardiography improved the visualization of 3-dimensional echocardiography ultrasound images, decreased the time required for surgical task completion, and increased the precision of instrument navigation, potentially improving the safety of beating-heart intracardiac surgical interventions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional echocardiography-guided beating-heart surgery without cardiopulmonary bypass: a feasibility study.

BACKGROUND There is no current acceptable approach for intracardiac beating-heart interventions. We have adapted real-time 3-dimensional echocardiography with specialized instrumentation to facilitate beating-heart repair of atrial septal defects and mitral valve plasty to investigate the feasibility of real-time 3-dimensional echocardiography-guided cardiac surgery. METHODS In experiment I a...

متن کامل

Robotic Motion Compensation for 3D Ultrasound-Guided Beating Heart Surgery

Beating heart surgeries offer significant health benefits to patients by removing the need for the heart-lung machine and its attendant side effects. These surgeries are challenging to perform and only feasible in certain types of procedures because of the rapid movement of the heart. Equipping the surgeon with fast, actuated, and intelligent surgical instruments that automatically compensate f...

متن کامل

Real-Time Processing of Three Dimensional Ultrasound for Intracardiac Surgery

Real-time three-dimensional ultrasound has been demonstrated as a viable tool for guiding surgical procedures. This visualization technique enables a range of new minimally invasive techniques in cardiac surgery. Ultrasound permits visualization through the opaque blood pool in the heart, and the advent of real-time 3DUS overcomes difficulties with 3D spatial perception in conventional 2D ultra...

متن کامل

Annular sizing using real-time three-dimensional intracardiac echocardiography-guided trans-catheter aortic valve replacement

OBJECTIVE Transcatheter aortic valve replacement (TAVR) has been established as an alternative therapy for patients with severe aortic stenosis who are unfit for the surgical aortic valve replacements. Pre and periprocedural imaging for the TAVR procedure is the key to procedural success. Currently transesophageal echocardiography (TOE), including real-time three-dimensional (RT-3D) imaging TOE...

متن کامل

A three-dimensional echocardiographic comparison of a deep pericardial stitch versus an apical suction device for heart positioning during beating heart surgery.

BACKGROUND Heart positioning during beating heart surgery produces significant haemodynamic compromise either when a deep pericardial stitch (DPS) or apical suction devices (ApSDs) are used. In this study the two techniques' haemodynamic performance and effect on intracardiac structures were compared through transoesophageal echocardiography (TEE) obtained volume measurements and three-dimensio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of thoracic and cardiovascular surgery

دوره 135 6  شماره 

صفحات  -

تاریخ انتشار 2008