3D simulation of the image formation in soft x-ray microscopes.

نویسندگان

  • Mårten Selin
  • Emelie Fogelqvist
  • Anders Holmberg
  • Peter Guttmann
  • Ulrich Vogt
  • Hans M Hertz
چکیده

In water-window soft x-ray microscopy the studied object is typically larger than the depth of focus and the sample illumination is often partially coherent. This blurs out-of-focus features and may introduce considerable fringing. Understanding the influence of these phenomena on the image formation is therefore important when interpreting experimental data. Here we present a wave-propagation model operating in 3D for simulating the image formation of thick objects in partially coherent soft x-ray microscopes. The model is compared with present simulation methods as well as with experiments. The results show that our model predicts the image formation of transmission soft x-ray microscopes more accurately than previous models.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical klystron FEL scheme for x-ray coherent harmonic generation at ISLF storage ring

The possibility of inserting an optical klystron on the storage ring of an Iranian Light Source Facility as a Synchrotron Radiation Free electron Laser for coherence harmonic generation in the soft x-ray spectrum has been studied. The study has been performed using the 3D FEL simulation code GENESIS 1.3 and in accordance with the available characteristic parameters of ISLF. Different potential ...

متن کامل

Laboratory cryo soft X-ray microscopy.

Lens-based water-window X-ray microscopy allows two- and three-dimensional (2D and 3D) imaging of intact unstained cells in their near-native state with unprecedented contrast and resolution. Cryofixation is essential to avoid radiation damage to the sample. Present cryo X-ray microscopes rely on synchrotron radiation sources, thereby limiting the accessibility for a wider community of biologis...

متن کامل

3D PSF Measurement for a Soft X-ray Microscope and Comparison to Theory

The transmission X-ray microscope’s 3D PSF exhibits an axial asymmetry that cannot be explained by an incoherent imaging model for either a lens or zone plate, with or without spherical aberration. OCIS codes: (340.7460) X-ray microscopy; (180.6900) Three-dimensional microscopy; (110.2990) Image Formation Theory

متن کامل

Partially coherent image formation with x-ray microscopes.

Image formation with partially coherent radiation is evaluated with the Hopkins formula and then applied to x-ray microscopy. Image characteristics expected from instruments with circular and annular pupils in partially coherent conditions are considered for two-point objects and a knife-edge object. The theoretically expected values for image characteristics that are easy accessible by an expe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 22 25  شماره 

صفحات  -

تاریخ انتشار 2014