Picosecond time-resolved laser pump/X-ray probe experiments using a gated single-photon-counting area detector.
نویسندگان
چکیده
The recent developments in X-ray detectors have opened new possibilities in the area of time-resolved pump/probe X-ray experiments; this article presents the novel use of a PILATUS detector to achieve X-ray pulse duration limited time-resolution at the Advanced Photon Source (APS), USA. The capability of the gated PILATUS detector to selectively detect the signal from a given X-ray pulse in 24 bunch mode at the APS storage ring is demonstrated. A test experiment performed on polycrystalline organic thin films of alpha-perylene illustrates the possibility of reaching an X-ray pulse duration limited time-resolution of 60 ps using the gated PILATUS detector. This is the first demonstration of X-ray pulse duration limited data recorded using an area detector without the use of a mechanical chopper array at the beamline.
منابع مشابه
X-rays only when you want them: optimized pump–probe experiments using pseudo-single-bunch operation
Laser pump-X-ray probe experiments require control over the X-ray pulse pattern and timing. Here, the first use of pseudo-single-bunch mode at the Advanced Light Source in picosecond time-resolved X-ray absorption experiments on solutions and solids is reported. In this mode the X-ray repetition rate is fully adjustable from single shot to 500 kHz, allowing it to be matched to typical laser exc...
متن کاملA high-repetition rate scheme for synchrotron-based picosecond laser pump/x-ray probe experiments on chemical and biological systems in solution.
We present the extension of time-resolved optical pump/x-ray absorption spectroscopy (XAS) probe experiments towards data collection at MHz repetition rates. The use of a high-power picosecond laser operating at an integer fraction of the repetition rate of the storage ring allows exploitation of up to two orders of magnitude more x-ray photons than in previous schemes based on the use of kHz l...
متن کاملDevelopment of Pulse Width Measurement Techniques in a Picosecond Range of Ultra-short Gamma Ray Pulses
Ultra-short gamma ray pulses of the picosecond and femtosecond range can be generated using laser Compton scattering with 90-degree collisions at the UVSOR-II electron storage ring. Measurement techniques for a gamma ray pulse width in the sub-picosecond to picosecond range are being developed. As the first stage of the development, we tested a pulse width measuring method for the gamma ray pul...
متن کاملPicosecond laser-pump, x-ray probe spectroscopy of GaAs
A laser-pump, x-ray probe spectroscopic experiment is described, and the results are shown. The Ga Ka x-ray fluorescence following x-ray absorption, at the Ga K absorption edge was measured, and its increase due to excitation with subpicosecond pulses of laser light at 4.6 eV photon energy was determined. The x-ray absorption, and thus the fluorescence, is increased for about 200 ps after the l...
متن کاملRecent Advances in the Generation of Pulsed Synchrotron Radiation Suitable for Picosecond Time-Resolved X-ray Studies
We describe the beamline optics, the shutters and the femtosecond laser used in pump & probe experiments down to 50 picosecond resolution. The performance of in-vacuum undulators is compared to in-air undulators. It is concluded that single-harmonic in-vacuum undulators are optimal for pump and probe experiments based on single-bunch exposures. These low-K undulators can produce a spectral flux...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of synchrotron radiation
دوره 16 Pt 3 شماره
صفحات -
تاریخ انتشار 2009