Actigraphy combined with EEG compared to polysomnography in sleep apnea patients.

نویسندگان

  • Ingo Fietze
  • Thomas Penzel
  • Markku Partinen
  • Jochen Sauter
  • Gert Küchler
  • Alexander Suvoro
  • Holger Hein
چکیده

An actigraph extended with electroencephalography (EEG), electroocculography (EOG) and electromyography (EMG) was compared to polysomnography in two studies on patients suffering from sleep disordered breathing. Study A with 30 subjects used a single lead EEG, and study B with 20 subjects used EOG and EMG in addition. Sleep was scored according to Rechtschaffen and Kales rules. Total sleep time (TST), sleep period time (SPT), sleep efficiency (SE), sustained sleep efficiency (SSE), sleep-onset latency (SL), and sleep stages were compared. For study A an epoch-by-epoch comparison of sleep stages revealed an overall agreement of 74.2%. Correlations were high for SE (0.98, p < 0.001), SSE (0.98, p < 0.001), TST (0.99, p < 0.001), SPT (0.99, p < 0.001), and SL (0.98, p < 0.001). Regarding the sleep stages, correlations were high for rapid eye movement (REM) (0.83, p < 0.001), light-sleep (0.78, p < 0.001), and deep sleep (0.73, p < 0.001). For study B, results of an epoch-by-epoch comparison of sleep stages showed an overall agreement of 75.5%. Correlations were high for SE (0.98, p < 0.001), SSE (0.98, p < 0.001), TST (0.87, p < 0.001), SL (0.98, p < 0.001), SPT (0.94, p < 0.001), and for rapid eye movement (REM) (0.91, p < 0.001), light-sleep (0.74, p < 0.001), and deep sleep (0.89, p < 0.001). In summary the study revealed high agreement between polysomnography and single lead EEG in sleep apnea patients. Deviations for REM were slightly higher for the single lead EEG compared to single lead EEG plus EOG/EMG. Both simplified systems proved to be reliable for comfortable out-patient sleep recording.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sleep monitoring by actigraphy in short-stay ICU patients

Sleep deprivation is common in intensive care unit (ICU) patients. The criterion standard for sleep monitoring, polysomnography, is impractical in ICU. Actigraphy (a wrist watch indicating amount of sleep) proved to be a good alternative in non-ICU patients, but not in prolonged mechanically ventilated patients, probably due to ICU-acquired weakness. Short-stay ICU patients do not suffer from I...

متن کامل

Apert Syndrome with Obstructive Sleep Apnea: A Case Report

Apert syndrome is a rare kind of craniosynostosis which is identified with fusion of cranial sutures during prematurity period and causes physical and intellectual disorders in younger ages. These patients may show symptoms of obstructive sleep apnea due to abnormal craniofacial shape. This article introduces a patient with Apert syndrome, with apnea symptoms, cyanosis, snoring, restlessness, n...

متن کامل

A novel adaptive wrist actigraphy algorithm for sleep-wake assessment in sleep apnea patients.

STUDY OBJECTIVES Current actigraphic algorithms are relatively less accurate in detecting sleep and wake in sleep apnea patients than in people without sleep apnea. In the current study, we attempted to validate a novel automatic algorithm, which was developed for actigraphic studies in normal subjects and patients with obstructive sleep apnea by comparing it on an epoch-by-epoch basis to stand...

متن کامل

Beyond standard polysomnography: Advantages and indications for use of extended 10–20 EEG montage during laboratory sleep study evaluations

PURPOSE Standard polysomnography (PSG) typically utilizes 4-6 channels of electroencephalography (EEG), which is inadequate to evaluate focal epileptiform activity. Though technical capability has long existed for more extensive EEG recording, few sleep laboratories have utilized this technique. The objective of this study was to determine the utility of combining PSG with 18-channel EEG in sel...

متن کامل

Practice parameters for the use of actigraphy in the assessment of sleep and sleep disorders: an update for 2007.

BACKGROUND Actigraphy is increasingly used in sleep research and the clinical care of patients with sleep and circadian rhythm abnormalities. The following practice parameters update the previous practice parameters published in 2003 for the use of actigraphy in the study of sleep and circadian rhythms. METHODS Based upon a systematic grading of evidence, members of the Standards of Practice ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiological measurement

دوره 36 3  شماره 

صفحات  -

تاریخ انتشار 2015