Normal and shear stresses on a residual limb in a prosthetic socket during ambulation: comparison of finite element results with experimental measurements.

نویسندگان

  • J E Sanders
  • C H Daly
چکیده

Interface stresses on a below-knee amputee residual limb during the stance phase of gait calculated using an analytical finite element model were compared with experimental interface stress measurements. The model was quasi-static and linear. Qualitatively, shapes of analytical and experimental interface stress waveforms were similar in that they were double-peaked with some distinct features apparent. However, quantitatively analytical resultant shear stress magnitudes were less than experimental values at all transducer measurement sites. Analytical normal stresses were less than experimental values at postero-proximal, postero-distal, and anteromedial proximal sites, but were greater than experimental values at antero-lateral distal and antero-lateral proximal sites. Anterior resultant shear angles were directed more distally in the model than in clinical data, an expected result since there was no relief for the tibial crest in the model. Model sensitivity analyses to shank loads showed interface normal and resultant shear stresses were most sensitive to axial force, sagittal bending moment, or sagittal shear force. The finite element model presented in this paper is significant because it contributes toward development of an analytical modeling technique to predict interface stress distributions for proposed prosthetic designs, provides insight into physical explanations of features apparent in interface stress waveforms (thereby enhancing understanding of interface mechanics), and provides insight into nonlinear characteristics that need to be added to improve the model.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Parametric analysis using the finite element method to investigate prosthetic interface stresses for persons with trans-tibial amputation.

A finite element (FE) model of the below-knee residual limb and prosthetic socket was created to investigate the effects of parameter variations on the interface stress distribution during static stance. This model was based upon geometric approximations of anthropometric residual limb geometry. The model was not specific to an individual with amputation, but could be scaled to approximate the ...

متن کامل

Interface shear stresses during ambulation with a below-knee prosthetic limb.

Shear stresses on a residual limb in a prosthetic socket are considered clinically to contribute to tissue breakdown in below-knee amputees. When applied simultaneously with normal stresses, they can cause injury within the skin or can generate an abrasion on the surface. To gain insight into shear stresses and parameters that affect them, interface stresses were recorded on below-knee amputee ...

متن کامل

Parametric analysis using the finite element method to investigate prosthetic interface stresses for persons with below-knee amputation

A finite element (FE) model of the below-knee residual limb and prosthetic socket was created to investigate the effects of parameter variations on the interface stress distribution during static stance . This model was based upon geometric approximations of anthropometric residual limb geometry . The model was not specific to an individual with amputation, but could be scaled to approximate th...

متن کامل

Finite element modeling of the contact interface between trans-tibial residual limb and prosthetic socket.

Finite element method has been identified as a useful tool to understand the load transfer mechanics between a residual limb and its prosthetic socket. This paper proposed a new practical approach in modeling the contact interface with consideration of the friction/slip conditions and pre-stresses applied on the limb within a rectified socket. The residual limb and socket were modeled as two se...

متن کامل

Generic, geometric finite element analysis of the transtibial residual limb and prosthetic socket.

Finite element (FE) analysis was used to investigate the stress distribution between the residual limb and prosthetic socket of persons with transtibial amputation (TTA). The purpose of this study was to develop a tool to provide a quantitative estimate of prosthetic interface pressures to improve our understanding of residual limb/prosthetic socket biomechanics and prosthetic fit. FE models of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of rehabilitation research and development

دوره 30 2  شماره 

صفحات  -

تاریخ انتشار 1993