Effects of Training on the Use of a Manual Microphone Shutoff on a BiCROS Device.

نویسندگان

  • Francis Kuk
  • Eric Seper
  • Chi Lau
  • Bryan Crose
  • Petri Korhonen
چکیده

BACKGROUND Bilateral contralateral routing of signals (BiCROS) hearing aids function to restore audibility of sounds originating from the side of the unaidable ear. However, when speech is presented to the side of the aidable ear and noise to the side of the unaidable ear, a BiCROS arrangement may reduce intelligibility of the speech signal. This negative effect may be circumvented if an on/off switch is available on the contralateral routing of signals (CROS) transmitter. PURPOSE This study evaluated if the proper use of the on/off switch on a CROS transmitter could enhance speech recognition in noise and sound localization abilities. The participants' subjective reactions to the use of the BiCROS, including the use of the on/off switch in real-life were also evaluated. RESEARCH DESIGN A between-subjects, repeated-measures design was used to assess differences in speech recognition (in quiet and in noise) and localization abilities under four hearing aid conditions (unaided, unilaterally aided, fixed BiCROS setting, and adjusted BiCROS setting) with speech and noise stimuli presented from different azimuths. Participants were trained on the use of the on/off switch on the BiCROS transmitter before testing in the adjusted BiCROS settings. Subjective ratings were obtained with the Speech, Spatial, and Sound Quality (SSQ) questionnaire and a custom questionnaire. STUDY SAMPLE Nine adult BiCROS candidates participated in this study. DATA COLLECTION AND ANALYSIS Participants wore the Widex Dream-m-CB hearing aid on the aidable ear for 1 week. They then wore the BiCROS for the remainder of the study. Speech recognition and localization testing were completed in four hearing aid conditions (unaided, unilateral aided, fixed BiCROS, and adjusted BiCROS). Speech recognition was evaluated during the first three visits, whereas localization was evaluated over the course of the study. Participants completed the SSQ questionnaire before each visit. The CROS questionnaire was completed at the final visit. A repeated measures analysis of variance with Bonferroni post hoc analysis was used to evaluate the significance of the results on speech recognition, localization, and the SSQ. RESULTS The results revealed that the adjusted BiCROS condition improved speech recognition scores by 20 rau (rationalized arcsine unit) when speech was presented to the aidable ear and localization by 37% when sounds are presented from the side of the unaidable ear over the fixed BiCROS condition. Statistically significant benefit on the SSQ was also noted with the adjusted BiCROS condition compared to the unilateral fitting. CONCLUSIONS These findings supported the value of an on/off switch on a CROS transmitter because it allows convenient selective transmission of sounds. It also highlighted the importance of instructions and practice in using the BiCROS hearing aid successfully.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Basic and advanced considerations in CROS and BiCROS fitting: streaming control and counselling

1 The Problem 1 The Gap 1 The Opportunity 1 Who are we trying to help? 3 What are the current solutions? 3 CROS systems 3 Candidacy 3 Expectations 4 BiCROS systems 5 Candidacy 5 Expectations 5 What’s coming down the line to solve this long standing problem? 6 Objective benefit from CROS/BiCROS systems 7 CROS/BiCROS – TRANSMISSION ON 7 CROS/BiCROS – TRANSMISSION OFF 8 So what does this all mean?...

متن کامل

بررسی میزان کاهندگی صدای وسایل حفاظت شنوایی برمبنای روش میکروفن داخل گوش MIRE در شرایط آزمایشگاهی

Introduction: Nominal noise reduction rate of the earmuff manufacturers can be different compared with the actual attenuation rate. The present study aimed to determine the actual noise reduction rate of common hearing protection devices using microphone in real ear method. Materials and Methods: In this study, five brands of common earmuffs used in Iranian industries were investigated on 30...

متن کامل

مقایسه تراز فشار صوت دو نوع کمباین مورد استفاده در ایران و بررسی برخی از عوامل موثر بر آن

Background and aims: High levels of noise that most operators of agricultural machinery are exposed to for a long time contribute to cause chronic fatigue and irreversible hearing loss. For this reason, occupational health and safety issues related to such machinary should be considered as a key criterion in the design of agricultural machinery and as a critical factor in the acceptance and sal...

متن کامل

Fabrication and Characterization of a New MEMS Capacitive Microphone using Perforated Diaphragm

In this paper, a novel single-chip MEMS capacitive microphone is presented. The novelties of this method relies on the moveable aluminum (Al) diaphragm positioned over the backplate electrode, where the diaphragm includes a plurality of holes to allow the air in the gap between the electrode and diaphragm to escape and thus reduce acoustical damping in the microphone. Spin-on-glass (SOG) was us...

متن کامل

A MEMS Capacitive Microphone Modelling for Integrated Circuits

In this paper, a model for MEMS capacitive microphone is presented for integrated circuits.  The microphone has a diaphragm thickness of 1 μm, 0.5 × 0.5 mm2 dimension, and an air gap of 1.0 μm. Using the analytical and simulation results, the important features of MEMS capacitive microphone such as pull-in voltage and sensitivity are obtained 3.8v and 6.916 mV/Pa, respectively while there is no...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American Academy of Audiology

دوره 26 5  شماره 

صفحات  -

تاریخ انتشار 2015