Development and Validation of RP-HPLC Method for Simultaneous Estimation of Picroside I, Plumbagin, and Z-guggulsterone in Tablet Formulation

نویسندگان

  • Meenakshi S. Akhade
  • Poonam A. Agrawal
  • K. S. Laddha
چکیده

The aim of the present work was to develop and validate a reversed-phase high-performance liquid chromatography method for the simultaneous estimation of picroside I, plumbagin, and Z-guggulsterone in a polyherbal formulation containing Picrorhiza kurroa, Plumbago zeylanica, and Commiphora wightii extracts. The analysis was performed on a C18 column using the mobile phase consisting of solvent A (acetonitrile) and solvent B (0.1% orthophosphoric acid in water) with the following gradient: 0-12 min, 25% A; 12-17 min, 25-80% A; 17-32 min, 80% A; and 32-37 min, 80-25% A at a flow rate of 1 ml/min. Ultraviolet detection was at 255 nm. The method was validated for accuracy, precision, linearity, specificity, and sensitivity as per the norms of the International Conference on Harmonization. From the validation study, it was found that the method is specific, accurate, precise, reliable, and reproducible. Good linear correlation coefficients (r(2)>0.900) were obtained for calibration plots in the ranges tested. Limits of detection were 2.700, 0.090 and 0.099 μg/ml and limits of quantification were 9.003, 0.310, and 0.330 μg/ml for picroside I, plumbagin, and Z-guggulsterone, respectively. Intra and interday relative standard deviation (RSD) of retention times and peak areas was less than 3.0%. Recovery was found to be 100.21% for picroside I, 102.5% for plumbagin, and 103.84% for Z-guggulsterone. The established method was appropriate and the three markers were well resolved, enabling efficient quantitative analysis of picroside I, plumbagin and Z-guggulsterone. The method is a rapid and cost-effective quality control tool for routine quantitative analysis of picroside I, plumbagin, and Z-guggulsterone in tablet dosage form.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous RP-HPLC and UV Spectroscopic Method Development and Validation for Estimation of Ibandronate Sodium in Bulk and Pharmaceutical Dosage Form

The present study describes a simple, accurate, precise and cost effective UV-Vis Spectroscopic and RP-HPLC method for the estimation of Ibandronate sodium (IBN). The determination of Ibandronate sodium (IBN) was performed by both UV and RP-HPLC method using 215 nm as the determination wavelength. The drug was dissolved in NaOH solution (0.1N NaOH) for estimation in UV and in distilled water fo...

متن کامل

A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms

A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms. Abstract The objective of the work is to develop and validate a new, simple, highly sensitive, stability indicating RP-HPLC method for simultaneous estimation of Dolutegravir and Rilpivirine in bulk and its dosage f...

متن کامل

Simultaneous estimation of amlodipine besylate and nebivolol hydrochloride in pharmaceutical tablets formulation by RP-HPLC using PDA detector

Background: The present work was undertaken with the aim to develop and validate a rapid and consistent RP-HPLC method in which the peaks will be appear with short period of time as per ICH Guidelines. Materials and Methods: The separation was achieved on a a stainless steel analytical column, Eclipse XDB plus C18 column (4.6 X 150 mm; 5 μm) in an isocratic mode. The mobile phase w...

متن کامل

Development and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.

AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm  4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...

متن کامل

Development and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.

AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm  4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 75  شماره 

صفحات  -

تاریخ انتشار 2013