Performance Evaluation of Protection Functions for Iec 61850-9-2 Process Bus Using Real-time Hardware-in-the-loop Simulation Approach

نویسندگان

  • Muhammad Shoaib ALMAS
  • Luigi VANFRETTI
چکیده

With the evolution of Process Bus (IEC 61850-9-2), there is a need to assess the performance of protection schemes using process bus against those where traditional copper wires are implemented. Differential protection is the fundamental and most commonly used protection for transformers, motors and generators. In this paper a power system is modelled in SimPowerSystems and is executed in real-time using Opal-RT’s eMEGAsim real-time simulator. Hardware-in-the loop validation of a process bus implementation for differential protection for a two winding transformer is done by using the differential protection feature in ABB’s RED-670 relay. The event reports generated by the ABB relay during Hardware-in-the-Loop testing are compared for three different scenarios i.e. complete process bus, hybrid process bus and complete traditional topology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of IEC 61850-9-2 Standard-Based Process Bus on the Operating Performance of Protection IEDS: Comparative Study

IEC 61850-9-2 is an international substation automation standard that proposes a Process Bus communication network between process level equipment and bay level Intelligent Electronic Devices (IEDs) used for power systems protection and control. This paper considers the drive towards the use of IEC 61850-9-2 Process Bus in substations. The impact of the IEC 61850-9-2 standard on the operating p...

متن کامل

Real Time Simulation Testing Using IEC 61850

-As IEC 61850 becomes more widely accepted in the electrical engineering community, it is important that the testing tools keep pace with this development. IEC 61850 presents new challenges to real time simulation and closed-loop testing of protective relays. Electrical interfaces used for binary signaling and voltage/current amplifiers must be replaced by an Ethernet connection and an IEC 6185...

متن کامل

1 Performance Evaluation of IEC 61850 Process

The paper presents the performance of a novel distributed bus differential protection scheme, which utilizes independent multi-principle advanced protection algorithms, including differential percent slope, delta phase directional comparison, rate of change of differential (ROCOD) currents, delta phase directional comparison on neutral current differential, and a check zone to secure the electr...

متن کامل

Demonstration of Adaptive Overcurrent Protection Using Iec 61850 Communications

This paper contains a description of an adaptive protection scheme that has been implemented and demonstrated in a hardware in the loop simulation environment using commercially available protection hardware and IEC 61850 communications. The implementation is based on an actual 11kV system which includes distributed generation and network automation. IEC 61850 communications offers several bene...

متن کامل

Performance Evaluation of Phasor Estimator within IEC 61850-9-2 Communication Network

This paper presents performance evaluation of a new architecture for phasor estimation within IEC 61850 substation Process-Bus. To benefit from the raw IEC 61850-9-2 Sampled Measured Values streamed with high sampling rate from various Merging Units at substation bay level, Unsented Kalman Filter is proposed to be utilized in the computation of Phasor at substation process level to enhance the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013