Real-time automated tracking and trapping system for sperm.

نویسندگان

  • Linda Z Shi
  • Jaclyn Nascimento
  • Charlie Chandsawangbhuwana
  • Michael W Berns
  • Elliot L Botvinick
چکیده

We have developed a microscope system for real-time single sperm tracking with an automated laser tweezers escape power assay. Phase contrast images of swimming sperm are digitized to the computer at video rate. The custom algorithm creates a region of interest centered about a sperm in response to a mouse click and performs all subsequent tasks autonomously. Microscope stage movement responds to feedback from video analysis of swimming sperm to center the sperm with respect to the field of view. For escape power assays, sperm are automatically relocated to the laser trap focus where they are held for a user-defined duration at fixed power, or held as laser power is gradually reduced. The sperm's position is automatically monitored to measure the laser power at which the sperm escapes the trap. Sperm are tracked for extended durations before and after laser trap experiments. Motility measurements including the curvilinear velocity and the absolute position of the sperm relative to the cell chamber are calculated and written to the hard drive at video rate. Experimental throughput is increased over 30 times compared to off-line data analysis. The efficacy of the "track and trap" algorithm is validated through examples and comparisons with the manually collected data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated motile cell capture and analysis with optical traps.

Laser trapping in the near infrared regime is a noninvasive and microfluidic-compatible biomedical tool. This chapter examines the use of optical trapping as a quantitative measure of sperm motility. The single point gradient trap is used to directly measure the swimming forces of sperm from several different species. These forces could provide useful information about the overall sperm motilit...

متن کامل

Comparison of glycolysis and oxidative phosphorylation as energy sources for mammalian sperm motility, using the combination of fluorescence imaging, laser tweezers, and real-time automated tracking and trapping.

The combination of laser tweezers, fluorescent imaging, and real-time automated tracking and trapping (RATTS) can measure sperm swimming speed and swimming force simultaneously with mitochondrial membrane potential (MMP). This approach is used to study the roles of two sources of ATP in sperm motility: oxidative phosphorylation, which occurs in the mitochondria located in the sperm midpiece and...

متن کامل

An interdisciplinary systems approach to study sperm physiology and evolution.

Optical trapping is a noninvasive biophotonic tool that has been developed to study the physiological and biomechanical properties of cells. The custom-designed optical system is built to direct near-infrared laser light into an inverted microscope to create a single-point three-dimensional gradient laser trap at the microscope focal point. A real-time automated tracking and trapping system (RA...

متن کامل

A Real-time Motion Tracking Wireless System for Upper Limb Exosuit Based on Inertial Measurement Units and Flex Sensors (TECHNICAL NOTE)

This paper puts forward a real-time angular tracking (motion capture) system for a low cost upper limb exosuit based on sensor fusion; which is integrated by an elastic sleeve-mitten, two inertial measurement units (IMU), two flex sensors and a wireless communication system. The device can accurately detect the angular position of the shoulder (flexion-extension, abduction-adduction and interna...

متن کامل

Feasibility Study of Real-time and Automated Monitoring of Iranian Rivers using 50-kHz Fluvial Acoustic Tomography System

Acoustic Tomography (AT) technique is an innovative method for real-time river monitoring. In this study, not only the accuracy of flow velocity measurement using 50 kHz AT system which is appropriate for narrow rivers (most Iranian rivers) is evaluated, but also its performance is compared with 30 kHz one which is used in wide rivers. The comparison results showed that the velocity resolutions...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Microscopy research and technique

دوره 69 11  شماره 

صفحات  -

تاریخ انتشار 2006