Vocal cord paralysis predicted by neural monitoring electrophysiologic changes with recurrent laryngeal nerve compressive neuropraxic injury in a canine model.

نویسندگان

  • Sidharth V Puram
  • Harold Chow
  • Che-Wei Wu
  • James T Heaton
  • Dipti Kamani
  • Gautham Gorti
  • Feng Yu Chiang
  • Gianlorenzo Dionigi
  • Marcin Barczyński
  • Rick Schneider
  • Henning Dralle
  • Kerstin Lorenz
  • Gregory W Randolph
چکیده

BACKGROUND Recurrent laryngeal nerve (RLN) injury is a known complication of thyroid/parathyroid surgery. Intraoperative nerve monitoring (IONM) has been used to gain more information regarding the functional status of the RLN intraoperatively; however, the electromyography (EMG) parameters of RLN after nontransection neuropraxic compressive injury remain unknown. METHODS We developed a canine model to identify IONM EMG correlates of postoperative vocal cord paralysis (VCP) using a standardized method to simulate surgical RLN compression sufficient to cause VCP. RESULTS Compression nerve injury decreased EMG amplitude and increased EMG latency, with a 60% increase in RLN threshold stimulation compared to preinjury values. If RLN amplitude decreases by 80% with an absolute amplitude of 300 μV or less in combination with a latency increase of 10% or more, then nerve injury and associated VCP is likely. CONCLUSION These results may help surgeons to prognosticate postoperative neural function and intraoperative decision-making regarding contralateral thyroid surgery. © 2015 Wiley Periodicals, Inc. Head Neck 38: E1341-E1350, 2016.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Continuous vagal IONM prevents recurrent laryngeal nerve paralysis by revealing initial EMG changes of impending neuropraxic injury: a prospective, multicenter study.

OBJECTIVES/HYPOTHESIS Existing intraoperative neuromonitoring (IONM) formats stimulate the recurrent laryngeal nerve (RLN) intermittently, exposing it to risk for injury in between stimulations. We report electrophysiologic parameters of continuous vagal monitoring, utilizing a novel real-time IONM format, and relate these parameters to intraoperative surgical maneuvers that delineate nascent a...

متن کامل

Posterior cricoarytenoid muscle electrophysiologic changes are predictive of vocal cord paralysis with recurrent laryngeal nerve compressive injury in a canine model.

OBJECTIVES/HYPOTHESIS Injury to the recurrent laryngeal nerve (RLN) is a dreaded complication of endocrine surgery. Intraoperative neural monitoring (IONM) has been increasingly utilized to assess the functional status of the RLN. Although the posterior cricoarytenoid muscle (PCA) is innervated by the RLN as the abductor of the larynx, PCA electromyography (EMG) is infrequently recorded during ...

متن کامل

Intraoperative Recurrent Laryngeal Nerve Monitoring in a Patient with Contralateral Vocal Fold Palsy

Recurrent laryngeal nerve injury can develop following cervical or thoracic surgery; however, few reports have described intraoperative recurrent laryngeal nerve monitoring. Consensus regarding the use of this technique during thoracic surgery is lacking. We used intraoperative recurrent laryngeal nerve monitoring in a patient with contralateral vocal cord paralysis who was scheduled for comple...

متن کامل

Incidence of vocal cord paralysis with and without recurrent laryngeal nerve monitoring during thyroidectomy.

OBJECTIVE To compare the incidence of postoperative vocal cord paresis or paralysis in a cohort of patients who underwent thyroidectomy with and without continuous recurrent laryngeal nerve (RLN) monitoring by a single senior surgeon. We hypothesize that continuous RLN monitoring reduces the rate of nerve injury during thyroidectomy DESIGN Retrospective medical chart review. SETTING Academi...

متن کامل

Intraoperative electrophysiologic monitoring of the recurrent laryngeal nerve during thyroid and parathyroid surgery: Experience with 1,381 nerves at risk.

OBJECTIVES The electrophysiologic responses of 1,381 recurrent laryngeal nerves (RLN) during monitored neck surgery were recorded and reviewed. STUDY DESIGN Retrospective case series. METHODS With institutional review board approval, we reviewed thyroid and other neck surgeries performed with intraoperative nerve monitoring (IONM) between the years 1995 and 2006. This list yielded consecuti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Head & neck

دوره 38 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2016