Sensitivity and specificity of PS/AA-modified nanoparticles used in malaria detection
نویسندگان
چکیده
Polystyrene (PS) nanoparticle (NP) copolymerized with acrylic acid (AA) and coloured monomer, i.e. 2,3,6,7-tetra(2,2'-bithiophene)-1,4,5,8-naphthalenetetracarboxylic-N,N'-di(2-methylallyl)-bisimide (ALN8T), was synthesized via the miniemulsion polymerization. Before applying for malaria antigen detection, the blue NP was conjugated with human polyclonal malaria IgG antibody (Ab) specific to Plasmodium falciparum. For the conjugation, three methods, i.e. physical adsorption, covalent coupling and affinity binding via streptavidin (SA) and biotin interaction, were employed. The optimum ratio of Ab to NPs used in each immobilization procedure and the latex agglutination test based on the reaction between Ab conjugated NPs and malaria patient plasma were investigated. All Ab-latex conjugates provided the high sensitivity for the detection of P. falciparum malaria plasma. The highest specificity to P. falciparum was obtained from using Ab-NPs conjugated via the SA-biotin interaction.
منابع مشابه
Selective Determination of Dopamine in the Presence of Ascorbic Acid and Uric Acid at Neutral pH Using a Silver Nanoparticles-modified Carbon Paste Electrode
Developing simple, sensitive and selective sensing systems for dopamine is important due to its biological significance. In this work, a silver nanoparticles-modified carbon paste electrode (AgNPs-CPE) has been constructed and used to detect of dopamine (DA) in the simultaneous presence of ascorbic acid (AA) and uric acid (UA) at neutral pH 7.0 by cyclic voltammetry. The modified electrode show...
متن کاملEvaluation of Microscopy Sensitivity, Specificity in Detection of P. falciparum and P. vivax, Using Monoplex real-time PCR, Gezira, Sudan
Background: Malaria is still account for 200 million cases annually. Microscopy is the gold standard technique for malaria parasites detection. PCR-based techniques can detect malaria infections with high sensitivity. The study aimed to evaluate the sensitivity of microscopy technique in the detection of P. falciparum and P. vivax, using monoplex real-time PCR, Gezira State, Central Sudan. Met...
متن کاملDetection of Ascorbic Acid in Biological Samples by a New Modified Glassy Carbon Electrode
The present work describes the construction of a new modified electrode by casting the appropriate mixture of a metallocene, which has been introduced in the experimental part, as a mediator at the surface of glassy carbon (GC) electrode. The proposed modified GC electrode was used for the determination of ascorbic acid (AA) in phosphate buffer (PB) solution (pH = 4.0). When compared to bare GC...
متن کاملComparison of the sensitivity and specifity of modified Rose Bengal and ELISA test in the diagnosis of brucellosis
Background and Aim: Brucellosis is a zoonotic disease and is one of the major health problems in our country. Considering its nonspecific symptoms, diagnosis of this disease is often made by laboratory methods. The purpose of the present study was to compare the sensitivity and specificity of ELISA and a relatively new modified Rose Bengal test in the diagnosis of brucellosis. Material and Meth...
متن کاملVoltammetric determination of amitriptyline based on graphite screen printed electrode modified with a Copper Oxide nanoparticles
A novel electrochemical sensor was proposed for the determination of amitriptyline based on the copper oxide (CuO) nanoparticles modified graphite screen-printed electrode. CuO nanoparticles were used to enhance the surface area of the electrode and then improve the sensitivity of the electrochemical sensor. Amitriptyline electrochemical response characteristics of the modified electrode in a p...
متن کامل