Stereoselective determination of S-naproxen in tablets by capillary electrophoresis.
نویسندگان
چکیده
A capillary electrophoresis (CE) method was developed for the stereoselective determination of the non-steroidal anti-inflammatory drug (NSAID), S-naproxen, in tablets. Several beta-cyclodextrin derivatives (CDs) were tested as chiral selectors, including sulfobutyl-beta-CD (SBCD), carboxymethyl-beta-CD (CMCD), dimethyl-beta-CD (DMCD) and trimethyl-beta-CD (TMCD), in a phosphoric acid/triethanolamine pH 3 buffer. Under these conditions, the analyte was mainly present in an uncharged form and therefore, the use a neutral CD (DMCD or TMCD) alone could not lead to enantiomeric separation. On the contrary, by addition of a charged CD (SBCD or CMCD) to the running buffer, giving the analyte enantiomers an adequate mobility, chiral resolution could be achieved, although the resolution values obtained in this case were not quite satisfactory (Rs < 1.5). Dual systems, based on the use of mixtures of charged and neutral CDs, were then investigated. The SBCD/TMCD system was found to be particularly well suited to the enantioseparation of naproxen and after optimisation of the concentrations of both CDs, a resolution value of 5.4 could be obtained. The method was validated for the determination of R-naproxen (enantiomeric impurity) in the 0.1-2% range, using the racemic mixture of the analyte. A second validation was performed in the 50-150% range for the quantitation of S-naproxen. In both cases, good results with respect to linearity, precision and accuracy were obtained.
منابع مشابه
Cyclodextrine Screening for the Chiral Separation of Carvedilol by Capillary Electrophoresis
Carvedilol is administered as a racemic mixture of the R(+)- and S(-)-enantiomers, although it was demonstrated that the two enantiomers exhibit different pharmacological effects and stereoselective pharmacokinetics. The aim of this study was the evaluation of several native and derivatized cyclodextrines as chiral selectors for the separation of carvedilol enantiomers. Stereoselective interact...
متن کاملCyclodextrine Screening for the Chiral Separation of Carvedilol by Capillary Electrophoresis
Carvedilol is administered as a racemic mixture of the R(+)- and S(-)-enantiomers, although it was demonstrated that the two enantiomers exhibit different pharmacological effects and stereoselective pharmacokinetics. The aim of this study was the evaluation of several native and derivatized cyclodextrines as chiral selectors for the separation of carvedilol enantiomers. Stereoselective interact...
متن کاملValidated Method for the Determination of Piroxicam by Capillary Zone Electrophoresis and Its Application to Tablets
Simple and rapid capillary zone electrophoretic method was developed and validated in this study for the determination of piroxicam in tablets. The separation of piroxicam was conducted in a fused-silica capillary by using 10 mM borate buffer (pH 9.0) containing 10% (v/v) methanol as background electrolyte. The optimum conditions determined were 25 kV for separation voltage and 1 s for injectio...
متن کاملCyclodextrine Screening for the Chiral Separation of Carvedilol by Capillary Electrophoresis
Carvedilol is administered as a racemic mixture of the R(+)- and S(-)-enantiomers, although it was demonstrated that the two enantiomers exhibit different pharmacological effects and stereoselective pharmacokinetics. The aim of this study was the evaluation of several native and derivatized cyclodextrines as chiral selectors for the separation of carvedilol enantiomers. Stereoselective interact...
متن کاملChiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis
Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of pharmaceutical and biomedical analysis
دوره 18 4-5 شماره
صفحات -
تاریخ انتشار 1998