Poor agreement between respiratory variations in pulse oximetry photoplethysmographic waveform amplitude and pulse pressure in intensive care unit patients.
نویسندگان
چکیده
BACKGROUND To identify fluid responsiveness, a correlation between respiratory variations in pulse pressure (DeltaPP) and respiratory variations in pulse oximetry photoplethysmographic waveform amplitude (DeltaPOP) in mechanically ventilated patients has been demonstrated. To evaluate the agreement between the two methods, knowledge about the repeatability of the methods is imperative. However, no such data exist. Based on knowledge of slow oscillation in skin blood flow, the authors hypothesized that the variability of DeltaPOP would be larger than that of DeltaPP when calculations were performed continuously over a long recording period. METHODS Respiration, continuous invasive blood pressure, pulse oximetry, and skin microcirculation were recorded in 14 mechanically ventilated intensive care unit patients. No intravenous fluid challenges were given, and no other interventions were performed during the measurements. Seventy consecutive comparisons between DeltaPP and DeltaPOP were calculated for each of the 14 patients. RESULTS For all patients, DeltaPOP was 13.7 +/- 5.8% and DeltaPP was 5.8 +/- 2.6% (P < 0.001). There was a larger intraindividual (8.94 vs. 1.29; P < 0.001) and interindividual (26.01 vs. 5.57; P < 0.001) variance of DeltaPOP than of DeltaPP. In six patients, there was no significant correlation between DeltaPP and DeltaPOP. A Bland-Altman plot showed poor agreement between the two methods. CONCLUSION A large variability of DeltaPOP and a poor agreement between DeltaPP and DeltaPOP limits DeltaPOP as a tool for evaluation of fluid responsiveness in intensive care unit patients. This is in contrast to DeltaPP, which shows a small variability.
منابع مشابه
Nevius' 1894 discovery of modern anesthesia.
106:1189 –94 35. Golparvar M, Naddafnia H, Saghaei M: Evaluating the relationship between arterial pressure changes and indices of pulse oximetric plethysmography. Anesth Analg 2002; 95:1686–90 36. Natalini G, Rosano A, Franceschetti ME, Facchetti P, Bernardini A: Variations in arterial blood pressure and photoplethysmography during mechanical ventilation. Anesth Analg 2006; 103:1182– 8 37. Sol...
متن کاملRelation between respiratory variations in pulse oximetry plethysmographic waveform amplitude and arterial pulse pressure in ventilated patients
INTRODUCTION Respiratory variation in arterial pulse pressure is a reliable predictor of fluid responsiveness in mechanically ventilated patients with circulatory failure. The main limitation of this method is that it requires an invasive arterial catheter. Both arterial and pulse oximetry plethysmographic waveforms depend on stroke volume. We conducted a prospective study to evaluate the relat...
متن کاملRespiratory Variation in Pulse Oximetry: A Simple Fluid Responsiveness Parameter
Respiratory variation in arterial pulse pressure (ΔPP) has been shown to be the most accurate predictor of fluid responsiveness in mechanically ventilated patients, with a predictive cutoff value of 13%. However, this dynamic parameter is invasive and not widely available. The pulse oximetry plethysmographic (POP) signal resembles the arterial pressure waveform in both shape and amplitude varia...
متن کاملComparison between respiratory pulse oximetry plethysmographic waveform amplitude and arterial pulse pressure variations among patients with and without norepinephrine use.
OBJECTIVES Arterial pulse pressure respiratory variation is a good predictor of fluid response in ventilated patients. Recently, it was shown that respiratory variation in arterial pulse pressure correlates with variation in pulse oximetry plethysmographic waveform amplitude. We wanted to evaluate the correlation between respiratory variation in arterial pulse pressure and respiratory variation...
متن کاملPulse oximeter as a sensor of fluid responsiveness: do we have our finger on the best solution?
The pulse oximetry plethysmographic signal resembles the peripheral arterial pressure waveform, and the degree of respiratory variation in the pulse oximetry wave is close to the degree of respiratory arterial pulse pressure variation. Thus, it is tempting to speculate that pulse oximetry can be used to assess preload responsiveness in mechanically ventilated patients. In this commentary we bri...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesiology
دوره 109 5 شماره
صفحات -
تاریخ انتشار 2008