Simulation of airbag impact on eyes with different axial lengths after transsclerally fixated posterior chamber intraocular lens by using finite element analysis
نویسندگان
چکیده
PURPOSE To determine the biomechanical response of an impacting airbag on eyes with different axial lengths with transsclerally fixated posterior chamber intraocular lens (PC IOL). MATERIALS AND METHODS Simulations in a model human eye were performed with a computer using a finite element analysis program created by Nihon, ESI Group. The airbag was set to be deployed at five different velocities and to impact on eyes with three different axial lengths. These eyes were set to have transsclerally fixated PC IOL by a 10-0 polypropylene possessing a tensile force limit of 0.16 N according to the United States Pharmacopeia XXII. RESULTS The corneoscleral opening was observed at a speed of 40 m/second or more in all model eyes. Eyes with the longest axial length of 25.85 mm had the greatest extent of deformity at any given impact velocity. The impact force exceeded the tensile force of 10-0 polypropylene at an impact velocity of 60 m/second in all eyes, causing breakage of the suture. CONCLUSION Eyes with transsclerally fixated PC IOL could rupture from airbag impact at high velocities. Eyes with long axial lengths experienced a greater deformity upon airbag impact due to a thinner eye wall. Further basic research on the biomechanical response for assessing eye injuries could help in developing a better airbag and in the further understanding of ocular traumas.
منابع مشابه
Lens implant selection with absence of capsular support.
If contact lens or spectacle correction is not viable, little debate exists that the secondary placement of an intra-ocular lens (IOL) is the method of choice in the absence of capsular support. The choice of IOL mainly depends on the preoperative status of the eye (eg, aphakia in children) and the selected location for the implant. Theoretically, there are several IOL implantation approaches i...
متن کاملIris-sutured posterior chamber intraocular lens implantation during penetrating keratoplasty.
PURPOSE To evaluate the clinical indications and postoperative results of iris-sutured posterior chamber intraocular lens implants performed during penetrating keratoplasty. METHODS Medical records were retrospectively reviewed for preoperative indications and postoperative results of 342 consecutive patients (366 eyes) who underwent iris suturing of a posterior chamber intraocular lens impla...
متن کاملComplications after primary and secondary transsclerally sutured posterior chamber intraocular lens implantation.
This retrospective study analyses and compares early complications during the first month after primary and secondary posterior chamber implantation of transsclerally sutured IOL. The analysis covered medical records of 65 patients who underwent posterior chamber implantation of transsclerally sutured IOL at the Eye Clinic in Rijeka between 1998 and 2003. In 30 patients (group 1) lenses were im...
متن کاملComparison of Preoperative and Postoperative Ocular Biometry in Eyes with Phakic Intraocular Lens Implantations
PURPOSE To compare preoperative and postoperative ocular biometry in patients with iris-fixated phakic intraocular lens (pIOLs): Artisan and Artiflex. MATERIALS AND METHODS This study included 40 eyes with Artisan and 36 eyes with Artiflex pIOL implants. Anterior chamber depth (ACD) and axial length (AL) were measured by applanation ultrasonography (A-scan) and partial coherence interferometr...
متن کاملOptical principles, biomechanics, and initial clinical performance of a dual-optic accommodating intraocular lens (an American Ophthalmological Society thesis).
PURPOSE To design and develop an accommodating intraocular lens (IOL) for endocapsular fixation with extended accommodative range that can be adapted to current standard extracapsular phacoemulsification technique. METHODS Ray tracing analysis and lens design; finite element modeling of biomechanical properties; cadaver eye implantation; initial clinical evaluation. RESULTS Ray tracing anal...
متن کامل