A Sensitivity Dosimetry Study of the Setup Uncertainties during Machine Commissioning and Annual QA

نویسندگان

  • Vi Nhan Nguyen
  • Brian Wang
  • Chengyu Shi
  • V. N. Nguyen
چکیده

This study is to investigate three common potential setup uncertainties during Linac commissioning and annual QA and to evaluate how these uncertainties propagate into the quality of beam profiles and patient dosimetry using gamma analysis. Three uncertainty scenarios were purposely introduced for gantry position tilted from 0 ̊ 3 ̊ (scenario 1), isocenter position misaligned from 0 6 mm (scenario 2) and SAD changed from 99.5 103 cm (scenario 3). A 60 × 60 × 60 cm3 water phantom cube was created to replicate a 3D water tank in VarianEclipse (V.11) treatment planning system (Varian Medical Systems, Palo Alto, CA). For each scenario, beam data profiles (crossline and diagonal) and PDD curves were calculated at different field sizes and depths for three energies: 6 MV, 6 MV-FFF and 10 MV-FFF. Gamma analysis method was used to compare a total of 263 profiles to baseline using a 1%/1mm parameter with 90% gamma passing rate criteria. For scenario 1, a ≥90% gamma passing rate and ≤1% dose difference were seen on both crossline and diagonal profiles, and PDD curves for gantry tilted up to 2 ̊. For 3 ̊ degree tilt, the gamma passing rate decreased to ≤90% at depth of ≥20 cm for 6MV/6MV-FFF and depth of ≥12 cm for 10MV-FFF. For scenario 2, a ≤90% gamma passing rate and ≥1% dose difference were seen at depths from dmax to 20 cm for all energies. For depths ≥20 cm, mostly ≥90% gamma passing rate and ≤1% dose difference were seen. For scenario 3, a ≥90% gamma passing rate and ≤1% dose difference were seen on ≤4 mm isocenter misalignments for all energies. In summary, gamma analysis of the beam profiles is a very sensitive test for SAD deviation scenarios and can reveal issues of sub millimeter setup uncertainty. However, it is not as sensitive for isocenter misalignment scenarios. The test is also more sensitive for FFF beams than flattening filter beams. How to cite this paper: Nguyen, V.N., Wang, B. and Shi, C.Y. (2016) A Sensitivity Dosimetry Study of the Setup Uncertainties during Machine Commissioning and Annual QA. International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 5, 329-347. http://dx.doi.org/10.4236/ijmpcero.2016.54032 Received: October 13, 2016 Accepted: November 18, 2016 Published: November 21, 2016 Copyright © 2016 by authors and Scientific Research Publishing Inc. This work is licensed under the Creative Commons Attribution International License (CC BY 4.0). http://creativecommons.org/licenses/by/4.0/ Open Access

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a systemic change of Superficial X-ray tube characteristics

Introduction: Very low, Low and Medium X-ray machines are used extensively for Superficial Radiation Therapy mostly used for Basal Cell, Squamous Cell Carcinoma, and Melanoma skin cancers. In most of cases, Superficial X-ray Therapy (SXRT) is preferred to Electron beams generated using a linear accelerator. SXRT tube characteristics may vary with the use of the machine for a lo...

متن کامل

Commissioning the First Mobile Dedicated Accelerator for Intraoperative Electron Radiotherapy in Iran

Introduction: Intraoperative radiotherapy is a radiotherapy technique in which a high single fraction of radiation dose is delivered to the patient after surgery and Concurrent with anesthesia time. The most frequent method for IORT implementation is Intraoperative electron radiotherapy (IOERT), in which, some dedicated and high dose per pulse electron accelerators are employe...

متن کامل

Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...

متن کامل

Commissioning and early experience with a new generation low-energy linear accelerator in zahedan

Introduction: Since commissioning beam data are treated as a reference and ultimately used by treatment planning systems, it is vitally important that the collected data are of the highest quality to avoid dosimetric and patient treatment errors that may subsequently lead to a poor radiation outcome. Beam data commissioning should be performed with appropriate knowledge and pr...

متن کامل

Dosimetry tools and techniques for IMRT.

Intensity modulated radiation therapy (IMRT) poses a number of challenges for properly measuring commissioning data and quality assurance (QA) radiation dose distributions. This report provides a comprehensive overview of how dosimeters, phantoms, and dose distribution analysis techniques should be used to support the commissioning and quality assurance requirements of an IMRT program. The prop...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016