Salinity Effect on the Corona Onset for a 765 Kv Ac Substation Connector

نویسندگان

  • J. HERNANDEZ
  • J.-R. RIBA
  • J. SANLLEHI
  • R. BOSCH
چکیده

Outdoor substations placed in coastal areas are affected by saline environments. In the technical literature it is found extensive information regarding insulations problems in presence of saline environments [1]. The accumulation of salts and other contaminants promotes the onset of partial discharges on the devices subjected to very high voltages. Insulators are also affected by this phenomenon. While rainfall has a cleaning effect on the insulator surface, humidity enhances the corrosion effect and degrades the performance of insulation [2], favouring onset conditions for partial discharge.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Redesign process of a 765 kVRMS AC substation connector by means of 3D-FEM simulations

This paper shows the capabilities of applying the three-dimensional finite element method (3D-FEM) for designing complex-shaped substation connectors to operate at 765 kVRMS AC. To check this methodology, it was analyzed the feasibility of upgrading a 400 kVRMS substation connector to operate at 765 kVRMS. However, both experimental and simulation results conducted according to the ANSI/NEMA CC...

متن کامل

HV Substation Overvoltage Computation Taking into Account Frequency Dependent Transients on the Substation Grounding System

This paper describes methodology for the computation of the electromagnetic transients in the high voltage substations, taking into account transients on the substation grounding system. Simulation technology is based on the system decomposition. Interconnections between different subsystems are done in each time step using Thevenin equivalents. Frequency dependent impedance of grounding conduc...

متن کامل

Measurement of the Magnetic Fields from High-Voltage (230 kV) Substations in Tehran and Assessment of Their Effects

Introduction: Recent industrial developments in human societies have caused rapid advancements in technologies of production and distribution of electricity, which in turn result in enhancement of power networks and utilization of high voltages. These networks and the high voltages in transfer lines cause the exposure to electric and magnetic fields. In this study, the situation regarding the m...

متن کامل

Study on Lightning Intruding Overvoltage in Yantan Extension Substation

500kV substation is especially important to the grid of our country, once it encounters lightning damage, the safety and reliability of the whole power system will be directly affected. As lightning intruding waves will cause overvoltage on electric equipments by intruding from the transmission line or straightly stroking the substation, which seriously influences the insulation level of equipm...

متن کامل

Conductor Corona Noise Prediction on High Voltage Ac Lines

The conductor corona noise of four local 400 kV AC transmission lines is measured and compared to predictions. The prediction software developed is based on the EPRI semi-analytical approach using excitation functions and the theory of natural modes. The nature and accuracy of the prediction software is discussed along with relevant corona noise metrology issues encountered.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012