Three-year, randomized, sham-controlled trial of dexamethasone intravitreal implant in patients with diabetic macular edema.
نویسندگان
چکیده
PURPOSE To evaluate the safety and efficacy of dexamethasone intravitreal implant (Ozurdex, DEX implant) 0.7 and 0.35 mg in the treatment of patients with diabetic macular edema (DME). DESIGN Two randomized, multicenter, masked, sham-controlled, phase III clinical trials with identical protocols were conducted. Data were pooled for analysis. PARTICIPANTS Patients (n = 1048) with DME, best-corrected visual acuity (BCVA) of 20/50 to 20/200 Snellen equivalent, and central retinal thickness (CRT) of ≥300 μm by optical coherence tomography. METHODS Patients were randomized in a 1:1:1 ratio to study treatment with DEX implant 0.7 mg, DEX implant 0.35 mg, or sham procedure and followed for 3 years (or 39 months for patients treated at month 36) at ≤40 scheduled visits. Patients who met retreatment eligibility criteria could be retreated no more often than every 6 months. MAIN OUTCOME MEASURES The predefined primary efficacy endpoint for the United States Food and Drug Administration was achievement of ≥15-letter improvement in BCVA from baseline at study end. Safety measures included adverse events and intraocular pressure (IOP). RESULTS Mean number of treatments received over 3 years was 4.1, 4.4, and 3.3 with DEX implant 0.7 mg, DEX implant 0.35 mg, and sham, respectively. The percentage of patients with ≥15-letter improvement in BCVA from baseline at study end was greater with DEX implant 0.7 mg (22.2%) and DEX implant 0.35 mg (18.4%) than sham (12.0%; P ≤ 0.018). Mean average reduction in CRT from baseline was greater with DEX implant 0.7 mg (-111.6 μm) and DEX implant 0.35 mg (-107.9 μm) than sham (-41.9 μm; P < 0.001). Rates of cataract-related adverse events in phakic eyes were 67.9%, 64.1%, and 20.4% in the DEX implant 0.7 mg, DEX implant 0.35 mg, and sham groups, respectively. Increases in IOP were usually controlled with medication or no therapy; only 2 patients (0.6%) in the DEX implant 0.7 mg group and 1 (0.3%) in the DEX implant 0.35 mg group required trabeculectomy. CONCLUSIONS The DEX implant 0.7 mg and 0.35 mg met the primary efficacy endpoint for improvement in BCVA. The safety profile was acceptable and consistent with previous reports.
منابع مشابه
Anatomical effects of dexamethasone intravitreal implant in diabetic macular oedema: a pooled analysis of 3-year phase III trials
BACKGROUND/AIM To assess long-term effects of dexamethasone intravitreal implant (DEX implant) monotherapy on retinal morphology in diabetic macular oedema (DME). METHODS Two multicentre, masked, phase III studies with identical protocols randomised patients with DME, best-corrected visual acuity of 34-68 Early Treatment Diabetic Retinopathy Study letters and central subfield retinal thicknes...
متن کاملCombined Intravitreal Dexamethasone Implant And Micropulse Yellow Laser For Treatment Of Anti-VEGF Resistant Diabetic Macular Edema
PURPOSE To report the efficacy and safety of combined intravitreal dexamethasone implant and micropulse laser for anti-VEGF resistant diabetic macular edema. PATIENTS AND METHODS Prospective, non-controlled study that was conducted for twenty eyes with center-involved diabetic macular edema not responding to anti-VEGF therapy. Ozurdex intravitreal implant was injected to all eyes with subsequ...
متن کاملDexamethasone intravitreal implant in the treatment of diabetic macular edema
Diabetic macular edema (DME) resembles a chronic, low-grade inflammatory reaction, and is characterized by blood-retinal barrier (BRB) breakdown and retinal capillary leakage. Corticosteroids are of therapeutic benefit because of their anti-inflammatory, antiangiogenic, and BRB-stabilizing properties. Delivery modes include periocular and intravitreal (via pars plana) injection. To offset the s...
متن کاملDexamethasone intravitreal implant in previously treated patients with diabetic macular edema: subgroup analysis of the MEAD study
BACKGROUND Dexamethasone intravitreal implant 0.7 mg (DEX 0.7) was approved for treatment of diabetic macular edema (DME) after demonstration of its efficacy and safety in the MEAD registration trials. We performed subgroup analysis of MEAD study results to evaluate the efficacy and safety of DEX 0.7 treatment in patients with previously treated DME. METHODS Three-year, randomized, sham-contr...
متن کاملEffect of Intravitreal Dexamethasone Implant (Ozurdex®) in the Glycemic Control of Patients with Diabetic Macular Edema
Purpose: To evaluate the effect of intravitreal dexamethasone implant (Ozurdex®) in the glycemic control of patients with diabetic macular edema. Methods: Ten patients with diabetic macular edema received an intravitreal injection (IVI) of dexamethasone implant (DEX implant, Ozurdex®). Glycated haemoglobin (HbA1C) is analyzed before and three months after IVI. The real-time glycemic readings ar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ophthalmology
دوره 121 10 شماره
صفحات -
تاریخ انتشار 2014