Validation of orthopaedic bench models for trauma surgery.

نویسندگان

  • J J H Leong
  • D R Leff
  • A Das
  • R Aggarwal
  • P Reilly
  • H D E Atkinson
  • R J Emery
  • A W Darzi
چکیده

The aim of this study was to validate the use of three models of fracture fixation in the assessment of technical skills. We recruited 21 subjects (six experts, seven intermediates, and eight novices) to perform three procedures: application of a dynamic compression plate on a cadaver porcine model, insertion of an unreamed tibial intramedullary nail, and application of a forearm external fixator, both on synthetic bone models. The primary outcome measures were the Objective Structural Assessment of technical skills global rating scale on video recordings of the procedures which were scored by two independent expert observers, and the hand movements of the surgeons which were analysed using the Imperial College Surgical Assessment Device. The video scores were significantly different for the three groups in all three procedures (p < 0.05), with excellent inter-rater reliability (alpha = 0.88). The novice and intermediate groups specifically were significantly different in their performance with dynamic compression plate and intramedullary nails (p < 0.05). Movement analysis distinguished between the three groups in the dynamic compression plate model, but a ceiling effect was demonstrated in the intramedullary nail and external fixator procedures, where intermediates and experts performed to comparable standards (p > 0.6). A total of 85% (18 of 21) of the subjects found the dynamic compression model and 57% (12 of 21) found all the models acceptable tools of assessment. This study has validated a low-cost, high-fidelity porcine dynamic compression plate model using video rating scores for skills assessment and movement analysis. It has also demonstrated that Synbone models for the application of and intramedullary nail and an external fixator are less sensitive and should be improved for further assessment of surgical skills in trauma. The availability of valid objective tools of assessment of surgical skills allows further studies into improving methods of training.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does Computed Tomography Change our Observation and Management of Fracture Non-Unions?

  Background: The purpose of this study was to determine whether Multi-Detector Computed Tomography (MDCT) in addition to plain radiographs influences radiologists’ and orthopedic surgeons’ diagnosis and treatment plans for delayed unions and non-unions.   Methods: A retrospective database of 32 non-unions was reviewed by 20 observers. On a scale of 1 to 5, observers rated on X-Ray and a...

متن کامل

Total Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry

Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...

متن کامل

Is It “Fractured” or “Broken”? A Patient Survey Study to Assess Injury Comprehension after Orthopedic Trauma

the bone is “fractured” or “broken”. While orthopaedic surgeons consider these terms synonymous, patients appear tocomprehend the terms as having different meanings. Given the commonality of this frequently posed question, it may beimportant for providers to assess patients’ level of understanding in order to provide optimal care. The purpose of thisstudy is to evaluate patients’ comprehension ...

متن کامل

A Survey on Transfusion Status in Orthopedic Surgery at a Trauma Center

  Background: Increased costs and mortality associated with inappropriate blood transfusions have led to investigations about blood request and blood transfusion techniques. We investigated the transfusion status in patients who underwent orthopedic surgery in Poursina Hospital (Rasht, Iran) to optimizing blood usage and determine if a scheduled transfusion program for every orthopedic surgery ...

متن کامل

An Anteriorly Presenting ‘Wrap Around’ Popliteal Cyst

The article describes a case in which a popliteal cyst was identified presenting as a mass on the anterior aspect of theright tibia. This occurred as a result of polyethylene wear debris from previous total knee arthroplasty. Although alternativediagnoses for an anterior tibial mass are more likely, a popliteal cyst must be considered, particularly if the patient has ahistory of total knee arth...

متن کامل

Regulation of autophagy by AMP-activated protein kinase/ sirtuin 1 pathway reduces spinal cord neurons damage

Objective(s): AMP-activated protein kinase/sirtuin 1 (AMPK/SIRT1) signaling pathway has been proved to be involved in the regulation of autophagy in various models. The aim of this study was to evaluate the effect of AMPK/SIRT1 pathway on autophagy after spinal cord injury (SCI). Materials and Methods:The SCI model was established in rats in vivo and the primary spinal cord neurons were subject...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 90 7  شماره 

صفحات  -

تاریخ انتشار 2008