Simultaneous analysis of dopamine and homovanillic acid by high-performance liquid chromatography with wall-jet/thin-layer electrochemical detection.

نویسندگان

  • Yaping Zhou
  • Hongling Yan
  • Qingji Xie
  • Siyu Huang
  • Jiali Liu
  • Zou Li
  • Ming Ma
  • Shouzhuo Yao
چکیده

Wall-jet/thin-layer amperometric electrochemical detection (ECD) coupled with high-performance liquid chromatography (HPLC) was used here for the simultaneous analysis of dopamine (DA) and homovanillic acid (HVA) at a glassy carbon electrode. Compared with the conventional thin-layer mode and wall-jet mode, the presented wall-jet/thin-layer ECD has the advantages of enhanced capture of electroactive DA and HVA on the working electrode to give enhanced responses and more convenient washing/refreshment of the working electrode surface. Under optimized conditions, the HPLC-ECD calibration curves show good linearity from 0.01 to 100 μM for DA and HVA, and the limits of detection (LODs) obtained were 1.1 nM for DA and 0.7 nM for HVA which are lower than those obtained with an UV-vis detector and a commercial electrochemical detector. The method was tested on human urine with satisfactory results. The balance of response-signal, signal-background and noise level for our HPLC-ECD system is also discussed. In addition, a demethylation electrooxidation mechanism for HVA is suggested through potentiostatic bulk electrolysis, electrospray ionization-mass spectrometry, fluorescent spectrophotometry and cyclic voltammetry studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous determination of four monoamine metabolites and serotonin in cerebrospinal fluid by "high-performance" liquid chromatography with electrochemical detection; application for patients with Alzheimer's disease.

We describe an optimized, sensitive assay procedure for simultaneously determining 3-methoxy-4-hydroxyphenylglycol, 3,4-dihydroxyphenylacetic acid, and serotonin in human lumbar cerebrospinal fluid. The assay is based on liquid chromatography with an electrochemical detection system equipped with a newly developed, highly sensitive graphite electrode. Before assay, samples are deproteinized wit...

متن کامل

Liquid chromatography-electrochemical detection for studying the effects of tetrahydrobiopterin on monoamine neurotransmitters in rat striatum

Tetrahydrobiopterin (BH4) is an essential co-factor in the biosynthesis of monoamine neurotransmitters. A nano-Pt/Pd modified electrode as the electrochemical detector (ED) for high-performance liquid chromatography (HPLC) coupled with microdialysis sampling, is used to explore the effect of administration of BH4 on the monoamine neurotransmitters in the rat striatum. The researches demonstrate...

متن کامل

Determination of 18 ?-Glycyrrhetinic Acid in Glycyrrhiza glabra L. Extract by HPLC

A high performance liquid chromatography method was studied for determination of 18 ?-glycyrrhetinic acid in Glycyrrhiza glabra L. (licorice) extract. The operating condition were C-18 reversed phase column (VP-ODS, (250×4.6 mm, 5 mm)) at room temperature, acetonitril/phosphoric acid (3/1) as mobile phase, at flow rate of 0.6ml/min (0-8min), 0.4ml/min (8-20min) and UV detection at 230 nm. The...

متن کامل

Determination of 18 ?-Glycyrrhetinic Acid in Glycyrrhiza glabra L. Extract by HPLC

A high performance liquid chromatography method was studied for determination of 18 ?-glycyrrhetinic acid in Glycyrrhiza glabra L. (licorice) extract. The operating condition were C-18 reversed phase column (VP-ODS, (250×4.6 mm, 5 mm)) at room temperature, acetonitril/phosphoric acid (3/1) as mobile phase, at flow rate of 0.6ml/min (0-8min), 0.4ml/min (8-20min) and UV detection at 230 nm. The...

متن کامل

Analysis of glutamate, GABA, noradrenaline, dopamine, serotonin, and metabolites using microbore UHPLC with electrochemical detection.

The applicability of microbore ultrahigh performance liquid chromatography (UHPLC) with electrochemical detection for offline analysis of a number of well-known neurotransmitters in less than 10 μL microdialysis fractions is described. Two methods are presented for the analysis of monoamine or amino acid neurotransmitters, using the same UHPLC instrument. Speed of analysis of noradrenaline (NA)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 138 23  شماره 

صفحات  -

تاریخ انتشار 2013