Square Wave Voltammetry for Analytical Determination of Cadmium in Natural Water Using Ca10(PO4)6(OH)2-Modified Platinum Electrode
نویسندگان
چکیده
This paper reports on the development of a novel electrochemical assay for cadmium (II) in natural water, which involves the use of disposable hydroxyapatite modified platinum electrode (HAP/Pt). Cadmium (II) was preconcentrated on the surface of the modified electrode and adsorbed onto HAP and oxidized at E = –680 mV. The HAP-modified platinum electrode exhibited superior performance in comparison to the platinum electrode and surprisingly, yielded a higher electrochemical response. The best defined anodic peak was obtained with 0.2 mol L KNO3 pH 5.0 after 25 min of accumulation time. Using these conditions, the calibration plot was linear over the range 1 × 10 to 5 × 10 mol L Cd. The precision was examined by carrying out eight replicate measurements at a concentration of 2.5 × 10 mol L; the coefficient of variation was 2.9%. The method was applied to the determination of the analyte in river water samples. The interfereence of other metal ions on the voltammetric response of Cd(II) was studied. The HAP films was clearly observed in the SEM images and characterized by X-ray diffraction, IR spectroscopy and chemical analysis.
منابع مشابه
Voltammetric Determination of α-Lipoic Acid using Poly(Vanillin) Modified Platinum Electrode
In the present study electrochemical detection of α-lipoic acid (α-LA) was carried out with a poly(Vanillin) modified platinum electrode p(VA)/PtE in Brinton Robinson buffer (BR) solution. The platinum electrode surface’s was modified with cyclic voltammetry method. The prepared Pt electrode was characterized by cyclic voltammetry in ferrocyanide and scanning electron microscopy (SEM) images. T...
متن کاملPlatinum Nanoparticle Electrode Modified Iodine using Cyclic Voltammetry and Chronoamperometry for Determination of Ascorbic Acid
This study investigated the oxidation of ascorbic acid (Vitamin C) using a platinum nanoparticle electrode coated with an iodine monolayer, called a modified electrode. The electrode were grown using the cyclic voltammetry technique and the electrochemical measurements were taken using the cyclic voltammetry and chronoamperometric technique. In the case of platinum nanoparticle electrode modifi...
متن کاملDNA Biosensor for Determination of 5-Fluorouracil based on Gold Electrode Modified with Au and Polyaniline Nanoparticles and FFT Square Wave Voltammetry
In the present study, a new biosensor for 5-Fluorouracil was described using modified goldelectrode and Fast Fourier transform square wave voltammetry (FFT SWV). Calf thymus DNAimmobilization was on a gold electrode decorated with polyaniline and gold nanoparticles. Theelectrochemical characteristics of the electrodes were investigated by cyclic voltammetry, andelectroch...
متن کاملVoltammetric Determination of Curcumin in Spices using Platinum Electrode Electrochemically Modified with Poly(Vanillin-co-Caffeic Acid)
In this study a simple, highly sensitive, and selective electrochemical method was developed for determination of the low concentration curcumin (CUR) using a poly(vanillin-co-caffeic acid) p(Van-CA) modified platinum electrode. Electrode modification was carried out electrochemically with cyclic voltammetry (CV) method. For this purpose; a solution of 6 mM vanillin (Van) and 6 mM caff...
متن کاملDetermination of Bosentan in Pharmaceutical Preparations by Linear Sweep, Square Wave and Differential Pulse Voltammetry Methods
In this study, simple, fast and reliable cyclic voltammetry (CV), linear sweep voltammetry (LSV), square wave voltammetry (SWV) and differential pulse voltammetry (DPV) methods were developed and validated for determination of bosentan in pharmaceutical preparations. The proposed methods were based on electrochemical oxidation of bosentan at platinum electrode in acetonitrile solution containin...
متن کامل