Comparison of Fixation Methods for Scaphoid Nonunions

نویسندگان

  • N. Kubiak
  • Mitchell Keshner
  • Eric Fulkerson
  • Nader Paksima
چکیده

The purpose of this study was to analyze the relative biomechanical stability of three types of internal fixation with cancellous bone graft in a cadaveric, scaphoid nonunion model. A scaphoid nonunion model was created by removing a volar wedge of bone from the waist of the scaphoid in 18 fresh frozen human cadavers. Cancellous sawbone graft was inserted into the osteotomy site and three groups of six cadavers each were then internally fixed with a pair of parallel 0.045-inch K-wires, Mini-Acutrak screws, or Standard Acutrak screws, respectively for each group. The potted specimens were tested using an Instron tensile testing machine by applying force to the distal pole of the scaphoid. The load and stiffness were calculated at 2 mm and 4 mm of displacement. Results showed that both the Mini-Acutrak screw and the Standard Acutrak screw were statistically stronger and stiffer at 2 mm displacement than the pair of parallel 0.045-inch K-wires. No statistically significant difference between the Standard and Mini-Acutrak screws was noted at 2 mm displacement. At higher loads (4 mm displacement), the Standard Acutrak became statistically stronger and stiffer than the Mini-Acutrak screw. It was concluded that the Standard Acutrak screw followed by the Mini-Acutrak screw may be a better option than a pair of parallel 0.045-inch K-wires when treating scaphoid nonunions. The screws have increased strength of fixation and stiffness when compared to K-wires. Also, unlike the K wires, the Acutrak screws enhance fracture healing by achieving interfragmentary compression. Even in a cancellous bone graft model, interfragmentary compression was achieved and our concern that the bone graft would “spit out” was allayed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of scaphoid fractures and nonunions.

Scaphoid fractures are common but present unique challenges because of the particular geometry of the fractures and the tenuous vascular pattern of the scaphoid. Delays in diagnosis and inadequate treatment for acute scaphoid fractures can lead to nonunions and subsequent degenerative wrist arthritis. Improvements in diagnosis, surgical treatment, and implant materials have encouraged a trend t...

متن کامل

Scaphoid Fractures: A Comparison of Two Surgical Methods for Internal Fixation Using Either Herbert Screws or Multiple Pins

Background and Aims: Scaphoid fractures are the most common fractures of the wrist. This study compared the outcomes of two surgical internal fixation techniques, using either Herbert screws (HS group) or multiple pins (MP group), in the treatment of scaphoid fractures. Methods: This cross-sectional study was performed on 41 patients (23 in HS and 18 in MP groups) with unilateral scaphoid fract...

متن کامل

A technique for anterior wedge-shaped grafts for scaphoid nonunions with carpal instability.

This article presents a brief description of the following modifications of the original Fisk procedure for navicular nonunions with carpal instability: (1) preoperative calculation of exact scaphoid length and form based on comparative roentgenograms of the opposite wrist, (2) the use of a palmar approach, (3) the insertion of a wedge-shaped corticocancellous graft from the iliac crest after r...

متن کامل

Short report letter: Three-dimensional printed anatomical models in scaphoid surgery

When undertaking surgery for nonunion of scaphoid fractures, appreciation of the three dimensional (3D) anatomy and hence accurate restoration of the original shape of the bone is difficult. Computerised tomography (CT) is regularly used to evaluate scaphoid nonunions slice by slice before surgery. As a potential aid for surgical planning, we have developed a method for producing 3D printed ana...

متن کامل

Herbert screw fixation of scaphoid fractures.

We reviewed the records of 431 patients who had open reduction and internal fixation of the scaphoid performed by one surgeon (TJH) over a 13-year period. The Herbert bone screw provided adequate internal fixation without the use of plaster immobilisation, promoting a rapid functional recovery. On average, patients returned to work 4.7 weeks after surgery and wrist function was significantly im...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007