HyFlex Competition Instance Summary
نویسندگان
چکیده
This document shows the instances that were used for the CHeSC 2011 competition. These instances are available within the JAR file containing the HyFlex software framework[2] version used for the competition. The first four domains were released before the competition as training domains with 10 instances each. There are now 12 instances in each because we added two hidden instances for the competition. For the competition, these two hidden instances were added to three randomly selected training instances. The remaining two domains were hidden, and contain 10 instances each. For the competition, we selected 5 instances at random from each. Table 1 shows which instances were used from each domain, in the CHeSC 2011 competition.
منابع مشابه
A general purpose Hyper – Heuristic based on Ant colony optimization
In the plan of the CHESC2001 competition [1], an hyper heuristic has been designed based on the Ant Colony Optimization method (from now ACO). According to the competition goals, the algorithm was developed with the intention to produce an independent model of the problem domain and the particular instance to be solved. This means that the hyper-heuristic is abstracted from the features of each...
متن کاملHyFlex: A Benchmark Framework for Cross-Domain Heuristic Search
Automating the design of heuristic search methods is an active research field within computer science, artificial intelligence and operational research. In order to make these methods more generally applicable, it is important to eliminate or reduce the role of the human expert in the process of designing an effective methodology to solve a given computational search problem. Researchers develo...
متن کاملHyFlex nickel-titanium rotary instruments after clinical use: metallurgical properties.
AIM To analyse the type and location of defects in HyFlex CM instruments after clinical use in a graduate endodontic programme and to examine the impact of clinical use on their metallurgical properties. METHODOLOGY A total of 468 HyFlex CM instruments discarded from a graduate endodontic programme were collected after use in three teeth. The incidence and type of instrument defects were anal...
متن کاملEffect of autoclave sterilization on the cyclic fatigue resistance of thermally treated Nickel-Titanium instruments.
AIM To compare the cyclic fatigue resistance of HyFlex CM, Twisted Files (TF), K3XF, Race, and K3, and evaluate the effect of autoclave sterilization on the cyclic fatigue resistance of these instruments both before and after the files were cycled. METHODOLOGY Five types of NiTi instruments with similar size 30, .06 taper were selected: HyFlex CM, TF, K3XF, Race and K3. Files were tested in a...
متن کاملComparison of preparation of curved root canals with Hyflex CM and Revo-S rotary nickel-titanium instruments.
AIM To compare the shaping ability of three different nickel-titanium rotary instruments during the preparation of curved root canals in extracted teeth. METHODOLOGY A total of 60 root canals with curvatures ranging between 25° and 35° were divided into three groups of 20 canals. Based on radiographs taken prior to instrumentation, the groups were balanced with respect to the angle and the ra...
متن کامل