Detection of resting myocardial perfusion defects by SonoVue myocardial contrast echocardiography.

نویسندگان

  • Tamanna Nahar
  • Peng Li
  • Bettina Kuersten
  • Sanjay Batra
  • Mani A Vannan
چکیده

BACKGROUND SonoVue is a new microbubble contrast agent containing sulfur hexafluoride. We assessed the efficacy of SonoVue myocardial contrast echocardiography (MCE) to detect resting perfusion abnormalities. METHODS Nineteen adult patients with a wall motion abnormality in a screening echocardiogram were studied. Each patient received up to four bolus injections of 2.0 mL SonoVue (Bracco Diagnostics, Inc.) during echocardiographic examination using either B-mode(n = 12)or power Doppler(n = 7)imaging. Each patient also had SPECT nuclear perfusion imaging performed. Segmental assessment of myocardial perfusion from SonoVue MCE images were compared with corresponding SPECT nuclear images. RESULTS Using B-mode imaging, the mean number of views obtained with a single SonoVue injection ranged from 1.4 to 1.9, with 2 or 3 injections required for a complete examination. Ninety-four percent of segments were scored as diagnostic. Agreement between B-mode and SPECT images was 72% for segments with a perfusion defect, 86% for normal perfusion, and 80% for segments with either perfusion defect or normal perfusion (all views combined). Using power Doppler imaging, the mean number of views obtained with a single SonoVue injection ranged from 1.0 to 1.3, with 2 to 4 injections required for a complete examination. Sixty-eight percent of segments were scored as diagnostic. Agreement between power Doppler and SPECT images was 67% for perfusion defects, 53% for segments with normal perfusion, and 59% for segments with either perfusion defect or normal perfusion (all views combined). CONCLUSIONS SonoVue MCE has the potential to assess myocardial perfusion at rest. B-mode imaging was more accurate than power Doppler imaging when compared with SPECT nuclear imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of myocardial contrast echocardiography with NC100100 and Tc sestamibi SPECT for detection of resting myocardial perfusion abnormalities in patients with previous myocardial infarction

Objective—To determine whether myocardial contrast echocardiography (MCE) following intravenous injection of perfluorocarbon microbubbles permits identification of resting myocardial perfusion abnormalities in patients who have had a previous myocardial infarction. Patients and interventions—22 patients (mean (SD) age 66 (11) years) underwent MCE after intravenous injection of NC100100, a novel...

متن کامل

Quantification of resting myocardial blood flow velocity in normal humans using real-time contrast echocardiography. A feasibility study

BACKGROUND Real-time myocardial contrast echocardiography (MCE) is a novel method for assessing myocardial perfusion. The aim of this study was to evaluate the feasibility of a very low-power real-time MCE for quantification of regional resting myocardial blood flow (MBF) velocity in normal human myocardium. METHODS Twenty study subjects with normal left ventricular (LV) wall motion and norma...

متن کامل

Relationship between the location of the most severe myocardial perfusion defects, the most severe coronary artery stenosis and the site of subsequent myocardial infarction [Persian]

This study evaluated the relationship between the location of the most severe coronary artery stenosis and the subsequent acute myocardial infarction (AMI). Methods: Of 1590 patients who were admitted with a diagnosis of AMI, we identified 44 patients who had undergone previous myocardial perfusion SPECT. Thirty-one of these patients also had previous coronary angiography. The relationshi...

متن کامل

Real-time perfusion adenosine stress echocardiography versus myocardial perfusion adenosine scintigraphy for the detection of myocardial ischaemia in patients with stable coronary artery disease.

BACKGROUND Real-time perfusion (RTP) contrast echocardiography using low mechanical index power modulation technique allows for simultaneous myocardial perfusion and wall motion analysis. RTP-adenosine stress echocardiography (ASE) could be an alternative to dobutamine-atropine stress echocardiography; more tolerable for the patients and possibly similarly accurate. We aimed to evaluate RTP-ASE...

متن کامل

Assessment of myocardial perfusion using contrast echocardiography – Case report

Contrast echocardiography is a technique that improves endocardial demarcation and provides real-time data on blood circulation (blood flow, velocity). Left ventricle imaging study using contrast agents that cross the pulmonary circulation allows an improved visualization of endocardial tissue. This creates a more accurate ultrasound evaluation of left ventricular dimensions and its kinetics. C...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Echocardiography

دوره 20 6  شماره 

صفحات  -

تاریخ انتشار 2003