Aortic false aneurysm at the distal anastomotic suture line after aortic arch replacement; a case report with review of the literature.

نویسندگان

  • S Siminelakis
  • N G Baikoussis
  • E M Arnaoutoglou
  • G Papadopoulos
  • J Goudevenos
چکیده

Anastomotic pseudoaneurysm remains one of the main life-threatening complications after surgery on the thoracic aorta. We report a case with a history of ascending and aortic arch replacement and a false aneurysm creation at the anastomotic line found at the 2-year follow-up computed tomography. Either, due to incidental and asymptomatic finding and patient negation to any kind of intervention, it has been followed the medical treatment with blood pressure and heart rate control. In this, we discuss also the ways of treatment and the indication of any interventional therapy. Endovascular stent-grafting is a minimal invasive treatment for thoracic aortic aneurysm. However, its clinical usefulness for anastomotic false aneurysm following thoracic aortic surgery is unclear.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Rare Variation of Right Subclavian Artery Origin from Posterior Surface of Aortic Arch

Purpose: Several variations of aortic arch have been reported yet. In present study another variation of aortic arch was reported. Right subclavian artery arises from posterior surface of the distal end of the aortic arch. Case Report: we present a variation of an aorticarch in which right subclavian artery arisesfrom posterior surface of the distal end of the aortic arch and passing behind eso...

متن کامل

Mycotic aortic aneurysm as a postsurgical complication: report of a case and review of the literature

Mycotic aneurysms are localized and irreversible dilatations of the arteries caused by weakening and damaging the arterial wall by an invasive organism establishing infective arteritis. Mycotic aneurysm of the thoracic aorta is a rare event; however, it can be fatal if not diagnosed early or not treated appropriately. Clinical findings are usually nonspecific; however, c...

متن کامل

Aortic Pseudo aneurysm 3 Years after Interposition Tube Graft for Acute Dissection of Ascending Aorta

Introduction: Patients with primary acute aortic dissection are at higher risk of complications, including increasing aortic aneurysm diameter, aortic rupture, aortic pseudo aneurysm, and recurrent aortic dissection. Case presentation We presented the case of a recurrent pseudo aneurysm and rupture of the aorta in the distal a...

متن کامل

Successful Repair of Type a Aortic Dissection in a Term Pregnancy: A Case Report

Stanford type A acute aortic dissection (AAD) is a very rare complication, with potentially lethal consequences in pregnancy. In fact, pregnancy has been regularly associated with the possibility of aortic. dissection in almost half of young women. Herein, we present the case of a 38-year-old woman in her 37th week of pregnancy. The patient’s medical history was indicative of G4L2Ab1(4 gestaiti...

متن کامل

Stridor in a Newborn with Double Aortic Arch-A Case Report

Introduction: Double aortic arch (DAA) is a congenital anomaly of the aortic arch. It is the most common type of complete vascular ring. When it occurs, the connected segment of the aortic arch and its branches encircle the trachea and esophagus, leading to symptoms related to these two structures. Case Report: We present a case of a newborn baby who developed biphasic stridor immediately after...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European review for medical and pharmacological sciences

دوره 16 6  شماره 

صفحات  -

تاریخ انتشار 2012