A Simplified Pipeline for Motion Correction in Dual Gated Cardiac PET
نویسندگان
چکیده
Positron Emission Tomography (PET) is a nuclear imaging technique of increasing importance e.g. in cardiovascular investigations. However, cardiac and respiratory motion of the patient degrade the image quality due to acquisition times in the order of minutes. Reconstructions without motion compensation are prone to spatial blurring and affected attenuation correction. These effects can be reduced by gating, motion correction and finally summation of the transformed images. This paper describes a new and systematic approach for the correction of both cardiac and respiratory motion. Key contribution is the splitting of the motion into respiratory and cardiac components, which are then corrected individually. For the considered gating scheme the number of registration problems is reduced by a factor of 3, which considerably simplifies the motion correction pipeline compared to previous approaches. The subproblems are stabilized by averaging cardiac gates for respiratory motion estimation and vice versa. The potential of the novel pipeline is evaluated in a group study on data of 21 human patients.
منابع مشابه
Advanced Motion Correction Methods in PET
With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...
متن کاملRespiratory and cardiac motion correction in dual gated PET/MR imaging
LaTIM, INSERM, UMR 1101, Brest, France Respiratory and cardiac motion in PET/MR imaging leads to reduced quantitative and qualitative image accuracy. Correction methodologies involve the use of double gated acquisitions which lead to low signal-to-noise ratio (SNR) and to issues concerning the combination of cardiac and respiratory frames. The objective of this work is to use a generalized reco...
متن کاملReducing the respiratory motion artifacts in PET cardiology: A simulation study
Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent les...
متن کاملDual-Gated Motion-Frozen Cardiac PET with Flurpiridaz F 18.
UNLABELLED A novel PET radiotracer, Flurpiridaz F 18, has undergone phase II clinical trial evaluation as a high-resolution PET cardiac perfusion imaging agent. In a subgroup of patients imaged with this agent, we assessed the feasibility and benefit of simultaneous correction of respiratory and cardiac motion. METHODS In 16 patients, PET imaging was performed on a 4-ring scanner in dual card...
متن کاملComparing approaches to correct for respiratory motion in NH3 PET-CT cardiac perfusion imaging
AIM Respiratory motion affects cardiac PET-computed tomography (CT) imaging by reducing attenuation correction (AC) accuracy and by introducing blur. The aim of this study was to compare three approaches for reducing motion-induced AC errors and evaluate the inclusion of respiratory motion correction. MATERIALS AND METHODS AC with a helical CT was compared with averaged cine and gated cine CT...
متن کامل