False-negative HIV antibody test results.

نویسندگان

  • W Preiser
  • N S Brink
  • A Hayman
  • J Waite
  • P Balfe
  • R S Tedder
چکیده

Ideally HIV antibody tests have to be both extremely sensitive and able to recognize all known HIV subtypes. Three patients whose sera failed to react with a synthetic oligopeptide-based HIV antibody test are described in this report. The patients were a Pakistani male infected recently, an Australian male infected for several years, and a Ugandan woman with AIDS. The presence of anti-HIV antibodies was confirmed by means of a standard algorithm with different assay formats. All three sera failed to react in one antiglobulin enzyme-linked immunosorbent assay (ELISA) (Bioelisa HIV-1+2, Biokit SA). No single underlying reason could be identified for the assay failure in the three cases. The first patient, probably infected recently when first tested, was strongly positive by the same assay a year later, confirming the relative insensitivity of oligopeptide assays reported previously for detecting the early antibody response. The other two patients appear to have been infected for several years. Although unlikely to have been infected with a non-clade B virus, the sample from patient 2 lacked detectable antibody to the transmembrane glycoprotein (gp41), the site of the synthetic oligopeptides. Patient 3, of Ugandan origin, was found to be infected with a non-clade B virus. Although her serum reacted strongly to subtype B gp41 in Western blot, it failed to react in the antiglobulin ELISA. Since there appears to be no single common explanation for these three failures there is little opportunity to identify prospectively those situations where testing using assays employing synthetic oligopeptides on the solid phase is likely to fail.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Failure of A Novel, Rapid Antigen and Antibody Combination Test to Detect Antigen-Positive HIV Infection in African Adults with Early HIV Infection

BACKGROUND Acute HIV infection (prior to antibody seroconversion) represents a high-risk window for HIV transmission. Development of a test to detect acute infection at the point-of-care is urgent. METHODS Volunteers enrolled in a prospective study of HIV incidence in four African cities, Kigali in Rwanda and Ndola, Kitwe and Lusaka in Zambia, were tested regularly for HIV by rapid antibody t...

متن کامل

Human Immunodeficiency Virus Diagnostic Testing: 30 Years of Evolution.

A concern during the early AIDS epidemic was the lack of a test to identify individuals who carried the virus. The first HIV antibody test, developed in 1985, was designed to screen blood products, not to diagnose AIDS. The first-generation assays detected IgG antibody and became positive 6 to 12 weeks postinfection. False-positive results occurred; thus, a two-test algorithm was developed usin...

متن کامل

Evaluation of commercial HIV test kits used in Nigeria.

BACKGROUND Accurate and reliable diagnosis of HIV plays a central role in any effective HIV intervention. We decided to evaluate 4 commercial HIV test kits to determine their reliability for use in developing countries. METHODS Serum samples obtained from clients accessing tertiary health services at the STI clinic, Jos University Teaching Hospital were used to evaluate Sdbioline, Diaspot, De...

متن کامل

Screening and diagnostic performance of enzyme immunoassay for antibody to lymphadenopathy-associated virus.

In a multicenter cooperative study, an enzyme immunoassay (EIA) using purified antigen of lymphadenopathy-associated virus was compared with radioimmune precipitation (RIP) for detection of antibody to human immunodeficiency virus (HIV) in 634 patients with acquired immunodeficiency syndrome or related conditions, 687 apparently healthy persons at risk for HIV infection, 93 controls with cancer...

متن کامل

HIV false positive results and Flu vaccination

Abstract False positive results are the major problem influencing interpretation of Clinical Laboratory test. They are originated mostly in the other diseases, technical errors and the recent vaccination. The problem has been presented since 1991 is positive HIV test after influenza Vaccination (1). The False positive has been reported in Cases using Eliza, one of The most common test to screen...

متن کامل

Contamination with HIV antibody may be responsible for false positive results in specimens tested on automated platforms running HIV 4th generation assays in a region of high HIV prevalence

INTRODUCTION In South Africa where the prevalence of HIV infection is very high, 4th generation HIV antibody/p24 antigen combo immunoassays are the tests of choice for laboratory based screening. Testing is usually performed in clinical pathology laboratories on automated analysers. To investigate the cause of false positive results on 4th generation HIV testing platforms in public sector labor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of medical virology

دوره 60 1  شماره 

صفحات  -

تاریخ انتشار 2000