The pathology of failed McKee-Farrar implants: correlation with modern metal-on-metal-implant failure
نویسندگان
چکیده
The McKee-Farrar (MF) prosthesis was the first widely used total hip replacement (THR) to employ a metal-on-metal (MoM) articulation. These implants had a high rate of early aseptic loosening but a number achieved good long-term implant survival, stimulating the reintroduction of second and third generation implants of this type. In this study we analysed archival histopathology of periprosthetic tissues in twenty cases of MF aseptic implant failure to determine if there was evidence of an innate and adaptive immune response similar to that seen in modern MoM implants. The presence of macrophages, the extent of necrosis and the ALVAL response were graded semi-quantitatively. Variable but in most cases extensive tissue necrosis was associated with a heavy macrophage response to Cobalt-Chrome (Co-Cr) wear particles in periprosthetic tissues; most cases also contained evidence of a predominantly lymphocyte response which in eight cases was moderate or heavy (Oxford Grade 2/3). Our findings show that inflammatory and necrotic changes to deposition of Co-Cr wear particles are found in periprosthetic tissues of failed MF implants, indicating that there is an innate and adaptive response similar to that noted in second/third generation MoM implants; they also suggest that the pathobiological response to metal wear particles is likely to have contributed to MF implant failure in these cases.
منابع مشابه
Risk Factors and Early Survival Rate of Biomet 3i Dental Implants. A Retrospective Study
Introdouction: Although highly desirable outcomes and longterm survival of dental implant treatments are well documented, implant failures still occur due to various reasons. Several risk factors may impair implant survival including implant dimensions (length, diameter, and implant design), procedures, local bone density at the implant site, and patient-related risk factors such as age, smokin...
متن کاملCobalt-Alloy Implant Debris Induce HIF-1α Hypoxia Associated Responses: A Mechanism for Metal-Specific Orthopedic Implant Failure
The historical success of orthopedic implants has been recently tempered by unexpected pathologies and early failures of some types of Cobalt-Chromium-Molybdenum alloy containing artificial hip implants. Hypoxia-associated responses to Cobalt-alloy metal debris were suspected as mediating this untoward reactivity at least in part. Hypoxia Inducible Factor-1α is a major transcription factor invo...
متن کاملA Metal-Acrylic Bar for Splinting Implant Impression Copings
Precise transfer of three-dimensional position of dental implants from oral cavity to the cast needs special considerations in impression making. It has been suggested to splint the copings by bars or acrylic resin material before making impression. Some problems regarding to polymerization shrinkage of acrylic resin have been reported. In this study, we describe a metalacrylic bar tha...
متن کاملInfluence of head size on the development of metallic wear and on the characteristics of carbon layers in metal-on-metal hip joints
BACKGROUND AND PURPOSE Particles originating from the articulating surfaces of hip endoprostheses often induce an inflammatory response, which can be related to implant failure. We therefore analyzed the metal content in capsular tissue from 44 McKee-Farrar metal-on-metal hip prostheses (with 3 different head sizes) and we also analyzed the morphological structure of layers located on articulat...
متن کاملFailure of total hip implants: metals and metal release in 52 cases.
BACKGROUND The pathogenesis of total joint replacement failure is multifactorial. One hypothesis suggests that corrosion and wear of alloys result in metal ion release, which may then cause sensitization and even implant failure, owing to the acquired immune reactivity. OBJECTIVES To assess cobalt, nickel and chromium(VI) release from, and the metal composition of, failed metal-on-ethylene to...
متن کامل