Efficacy of a Bio-Absorbable Antibacterial Envelope to Prevent Cardiac Implantable Electronic Device Infections in High-Risk Subjects.

نویسندگان

  • Matthew J Kolek
  • Neel J Patel
  • Walter K Clair
  • S Patrick Whalen
  • Jeffrey N Rottman
  • Arvindh Kanagasundram
  • Sharon T Shen
  • Pablo J Saavedra
  • Juan C Estrada
  • Robert L Abraham
  • Christopher R Ellis
چکیده

INTRODUCTION Cardiac implantable electronic device (CIED) infections are potentially preventable complications associated with high morbidity, mortality, and cost. A recently developed bio-absorbable antibacterial envelope (TYRX™-A) might prevent CIED infections in high-risk subjects. However, data regarding safety and efficacy have not been published. METHODS AND RESULTS In a single-center retrospective cohort study, we compared the prevalence of CIED infections among subjects with ≥2 risk factors treated with the TYRX™-A envelope (N = 135), the nonabsorbable TYRX™ envelope (N = 353), and controls who did not receive an envelope (N = 636). Infection was ascertained by individual chart review. The mean (95% confidence interval) number of risk factors was 3.08 (2.84-3.32) for TYRX™-A, 3.20 (3.07-3.34) for TYRX™, and 3.09 (2.99-3.20) for controls, P = 0.3. After a minimum 300 days follow-up, the prevalence of CIED infection was 0 (0%) for TYRX™-A, 1 (0.3%) for TYRX™, and 20 (3.1%) for controls (P = 1 for TYRX™-A vs. TYRX™, P = 0.03 for TYRX™-A vs. controls, and P = 0.002 for TYRX™ vs. controls). In a propensity score-matched cohort of 316 recipients of either envelope and 316 controls, the prevalence of infection was 0 (0%) and 9 (2.8%), respectively, P = 0.004. When limited to 122 TYRX™-A recipients and 122 propensity-matched controls, the prevalence of CIED infections was 0 (0%) and 5 (4.1%), respectively, P = 0.024. CONCLUSIONS Among high-risk subjects, the TYRX™-A bio-absorbable envelope was associated with a very low prevalence of CIED related infections that was comparable to that seen with the nonabsorbable envelope.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of an antibacterial envelope is associated with reduced cardiac implantable electronic device infections in high-risk patients.

INTRODUCTION The incidence of cardiac implantable electronic device (CIED) infections has risen rapidly since 2004. A commercially available minocycline and rifampin impregnated antibacterial envelope has been associated with a low CIED infection rate. We performed a retrospective cohort study analyzing CIED infection rates in patients receiving an antibacterial envelope. METHODS Prospectivel...

متن کامل

Clinical use of antibacterial mesh envelopes in cardiovascular electronic device implantations

Cardiovascular implantable electronic device system infection is a serious complication of cardiac device implantation and carries with it a risk of significant morbidity and mortality. In the last 15 years, expansions of indications for cardiac devices have resulted in much higher volumes of much sicker patients being implanted, carrying significant risk of infection. Coagulase (-) Staphylococ...

متن کامل

Health and Economic Outcomes Associated with Use of an Antimicrobial Envelope as a Standard of Care for Cardiac Implantable Electronic Device Implantation.

INTRODUCTION Infection of cardiac implanted electrical devices (CIED) is a problem. In selected patients, use of an "antibacterial envelope" (AIGISRx®) is associated with low CIED infection rates. The value of this device when used as a standard of care is unclear. METHODS AND RESULTS Retrospective analysis of all patients (N = 1,476) who underwent CIED implantation at a single hospital. Duri...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

Arrhythmia Management Devices

811 The first cardiac implantable electronic device (CIED), the electronic pacemaker, maintains cardiac contraction during bradycardia. The implantable cardioverter-defibrillator (ICD) manages ventricular tachycardia (VT) or fibrillation (VF) and saves lives primarily through the use of high-energy shocks. The cardiac resynchronization therapy (CRT) device restores interventricular and intraven...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cardiovascular electrophysiology

دوره 26 10  شماره 

صفحات  -

تاریخ انتشار 2015