Assessing the Accuracy of Spatial Normalization of Diffusion Tensor Imaging Data in the Presence of Image Artifacts

نویسندگان

  • A. Orlichenko
  • R. J. Dawe
  • H. Peng
  • K. Arfanakis
چکیده

Introduction: Diffusion tensor imaging (DTI) is a non-invasive MR imaging technique that can be used to probe in-vivo the microstructural properties of brain tissue [1]. Accurate inter-subject spatial normalization of DTI data is crucial for voxel-based comparisons of neuronal structural integrity [2] and brain connectivity [3] across populations, as well as for the development of a white matter atlas [4]. The purpose of this work was to assess the effects of image artifacts on the accuracy of spatial normalization of DTI data. Materials and Methods: (MRI Scans) Ten normal subjects (30+-5 years of age, 20-40 years of age, 8 male, 2 female) participated in this study. DTI data with minimal artifacts were obtained with Turboprop-DTI, and data with fieldinhomogeneity-related artifacts were acquired with SE-EPI-DTI on a 3T GE scanner (General Electric, Waukesha, WI). The parameters for the Turboprop-DTI sequence were: TR=5secs, TE=94msecs, 16 k-space blades, FOV=24x24cm, 256x256 image matrix, 36 contiguous axial slices, and 3.5mm slice thickness. Diffusion weighted (DW) images of each slice were acquired using a minimum energy diffusion encoding scheme with 12 gradient directions and b=900sec/mm. Two images with no diffusion weighting (b=0sec/mm) were also acquired at the beginning of each scan. The scan time for TurbopropDTI was 18 minutes and 55 seconds. Most parameters for SE-EPI-DTI were identical to Turboprop-DTI, except that TR=5.4secs, TE=71.8msecs, 8 copies of the b=0sec/mm images and 4 copies of each DW image were obtained. The scan time for SE-EPI-DTI was 5 minutes and 2 seconds, and was selected such that the signal to noise ratio in the raw SE-EPIDTI data was similar to that in the Turboprop-DTI data. Each subject was also scanned with a 2D gradient-echo sequence with two echoes having TE1=5msecs, TE2=11.8msecs, TR=2secs, FOV=24x24cm, 36 contiguous axial slices, 3.5mm slice thickness, 128x128 image matrix. (Data Analysis) Distortions stemming from eddy-currents were corrected in the SE-EPI-DTI data of each subject by registering all DW volumes to the mean DW volume. Phase maps produced from the 2D gradient-echo images were used to correct field inhomogeneity-related distortions in the SE-EPI-DTI data. Further processing was carried out to remove skull and noise outside of the brain in SE-EPI-DTI and Turboprop-DTI datasets. Diffusion tensors were then estimated for both groups of data. A population-based methodology [5] was employed to spatially transform each group of DTI data to the corresponding average space of the population. In this process, each dataset in a group was registered to every other dataset, and the average of these transformations was used to transfer the dataset into population space. Individual registrations were carried out by a piecewise-affine registration algorithm with millions of degrees of freedom and explicit optimization of tensor orientation (DTI-TK, University of Pennsylvania, PA) [6]. Assessment of spatial normalization accuracy for the two groups of DTI data was performed by means of the coherence of primary eigenvectors in white matter [7]. Results and Discussion: Residual susceptibility artifacts were present in the corrected SE-EPIDTI data (Fig.1.a,b). No visible artifacts were included in the Turboprop-DTI data (Fig.1.c,d). Histograms of coherence values in white matter demonstrated that normalization of datasets with minimal artifacts resulted in relatively more white matter voxels with high coherence values, than data with visible artifacts (Fig.2). Higher coherence values suggest improved matching of the primary eigenvector of diffusion tensors across subjects. Moreover, maps of the coherence for the two groups of data showed that the greatest differences in coherence occurred in major white matter structures throughout the brain (Fig.3). Table 1 shows significant differences in coherence values of 3 white matter structures when using data with minimal and visible artifacts. Therefore, it was concluded that data with minimal artifacts increase the accuracy of spatial normalization in DTI. Finally, the amount of artifacts included in SE-EPI-DTI data varies for different subjects, and different imaging parameters (e.g. slice thickness, TE, acceleration factor for parallel imaging, etc.). However, the purpose of this work was not to compare the two acquisition sequences and different imaging parameters, but to evaluate the effects of artifacts on the accuracy of spatial normalization. Data with more severe artifacts than those in the corrected SE-EPI-DTI data used here is expected to further reduce the accuracy of spatial normalization, while data with fewer artifacts is expected to produce coherence values that are more similar to those obtained for the Turboprop-DTI data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

The Benefits and implementations of Diffusion tensor imaging and Neural Fiber Tractography in Brain Surgery

Background and Aim: The methods for detecting brain activation with fMRI, MRI provides a way to measure the anatomical connections which enable lightning-fast communication among neurons that specialize in different kinds of brain functions. Diffusion tensor imaging is able to measure the direction of bundles of the axonal fibers which are all aligned. Besides mapping white matter fiber tracts,...

متن کامل

Evaluation of Soft Tissue Sarcoma Tumors Electrical Conductivity Anisotropy Using Diffusion Tensor Imaging for Numerical Modeling on Electroporation

Introduction: There is many ways to assessing the electrical conductivity anisotropyof a tumor. Applying the values of tissue electrical conductivity anisotropyis crucial in numerical modeling of the electric and thermal field distribution in electroporationtreatments. This study aims to calculate the tissues electrical conductivityanisotropy in patients with sarcoma tumors using diffusion tens...

متن کامل

Differentiation of Edematous, Tumoral and Normal Areas of Brain Using Diffusion Tensor and Neurite Orientation Dispersion and Density Imaging

Background: Presurigical planning for glioma tumor resection and radiotherapy treatment require proper delineation of tumoral and peritumoral areas of brain. Diffusion tensor imaging (DTI) is the most common mathematical model applied for diffusion weighted MRI data. Neurite orientation dispersion and density imaging (NODDI) is another mathematical model for DWI data modeling.Objective: We stud...

متن کامل

Comparison of Count Normalization Methods for Statistical Parametric Mapping Analysis Using a Digital Brain Phantom Obtained from Fluorodeoxyglucose-positron Emission Tomography

Objective(s): Alternative normalization methods were proposed to solve the biased information of SPM in the study of neurodegenerative disease. The objective of this study was to determine the most suitable count normalization method for SPM analysis of a neurodegenerative disease based on the results of different count normalization methods applied on a prepared digital phantom similar to one ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009