Choice of an ELISA assay for screening postmortem blood for amphetamine and/or methamphetamine.

نویسندگان

  • Tom Kupiec
  • Lacinda DeCicco
  • Vina Spiehler
  • Gary Sneed
  • Philip Kemp
چکیده

The object of this study was to evaluate the suitability of the Neogen Corp. microtiter plate enzyme-linked immunoassays (ELISA) for the screening of postmortem blood for amphetamine and methamphetamine and to choose the more appropriate assay for screening. Forty-seven postmortem whole blood specimens were obtained from drug-involved deaths, which had been screened and confirmed positive for methamphetamine and/or amphetamine. Eighty-five negative specimens were obtained from non-amphetamines-involved deaths, 17 of which involved decomposition. Specimens were tested using the Neogen Amphetamine Ultra and Neogen Methamphetamine/MDMA microtiter plate ELISA assays. No matrix effects were found for whole blood in these assays, and a dilution of 1:5 was chosen to facilitate pipetting and to bring the IC50 of the microtiter plate ELISA assay within the range of amphetamines concentrations encountered in medical examiner specimens. True positives, true negatives, false positives, and false negatives were determined relative to gas chromatography-mass spectrometry (GC-MS) and graphed for the ELISA. From these graphs and the receiver operating curves (ROC), the optimal cut-off for the Neogen Methamphetamine/MDMA ELISA was 50 ng/mL methamphetamine equivalents and the optimum cut-off for the Neogen Amphetamine Ultra ELISA was 100 ng/mL amphetamine equivalents. The Neogen Methamphetamine ELISA had a sensitivity of 93.6% +/- 3.5% and a specificity of 77.6% +/- 4.5% versus GC-MS at the cut-off of 50-ng/mL methamphetamine equivalents. The Neogen Amphetamine Ultra ELISA had a sensitivity of 95.7% +/- 3.0% and a specificity of 72.9% +/- 5.2% versus GC-MS at the 100-ng/mL amphetamine equivalents cut-off. The areas under the ROCs were equivalent for the two ELISA assays.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Antemortem and postmortem methamphetamine blood concentrations: three case reports.

We compare antemortem whole-blood to postmortem peripheral blood concentrations of methamphetamine and its metabolite amphetamine in three medical examiner cases. Antemortem specimens, initially screened positive for methamphetamine by ELISA, were subsequently confirmed, together with the postmortem specimens, by GC-MS analysis following solid-phase extraction. Methamphetamine peripheral blood ...

متن کامل

Acute methylone intoxication in an accidental drowning--a case report.

A 19-year-old woman who was known to use illicit drugs (ecstasy and marijuana) was found floating in the ocean 100 yards from the beach. When last seen the previous evening, she had said to a friend that she was going to "get in the water." Reports to police indicated that she "may have been on ecstasy." There were no notes of a suicidal nature, illicit drugs, drug paraphernalia, tobacco cigare...

متن کامل

Analytical Performance Evaluation of EMIT#{174} II Monoclonal Amphetamine/ Methamphetamine Assay: More Specificitythan EMIT#{174} d.a.u.TMMonoclonal Amphetamine/Methamphetamine Assay

We evaluated a new EMIT#{174} II monoclonal amphetamine! methamphetamine assay for screening human urine by comparing itwith the EMIT#{174} d.a.u. monoclonal amphetamine/methamphetamine assay and a fluorescence polarization assay. The EMIT II assay has a cutoff of 1 mg!L d-methamphetamine. The EMIT II and EMIT d.a.u. assays were run on a BM/Hitachi 704 analyzer; for the fluorescence polarizatio...

متن کامل

Determination of Amphetamine and Methamphetamine by Dispersive Liquid Phase Micro-extraction: A Novel Experimental Approach

Background: A syringe to syringe dispersive liquid phase micro-extraction-floating organic drop was applied and used for the simultaneous extraction and pre-concentration of trace amounts of amphetamine (AMP) and methamphetamine (MAMP) in urine samples. The extracted analytes were determined by high performance liquid chromatography along with diode array detection. Materials & Methods: In thi...

متن کامل

Multiplex assay of amphetamine, methamphetamine, and ecstasy drug using CEDIA technology.

Using Microgenics unique technology, cloned enzyme donor immunoassay (CEDIA), the multiplex assay (CEDIA Amphetamines/Ecstasy) has been developed for the detection of amphetamine, methamphetamine, and ecstasy drugs at cutoff level either of 500 ng/mL or 1000 ng/mL applicable for either qualitative screening or semiquantitative measurement. The multiplex assay detects the total concentration of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of analytical toxicology

دوره 26 7  شماره 

صفحات  -

تاریخ انتشار 2002