Fiberoptic sensor for noninvasive measurement of variceal pressure.

نویسندگان

  • D-R Kong
  • B-B He
  • A-J Wu
  • J-G Wang
  • F-F Yu
  • J-M Xu
چکیده

We present a newmeasuring probe based on a miniature fiberoptic pressure sensor that can measure esophageal variceal pressure. The probe consists of an outer flexible chamber filled with a pressure transmission medium, at the center of which is positioned the fibreoptic sensor with diameter of 0.5mm (FOP-F125, FISO Technologies Inc., Quebec, Canada) (●" Fig.1). The single-column, flexible chamber has a 0.03-mm wall thickness and the chamber wall is made of polyurethane. The sensor within the medium is attached at one end to a connecting rod. When the membrane on the sensor chip is exposed to a rise in pressure in the surrounding medium, the light returning to the control unit is altered in accordance with the pressure deformations of the membrane and the altered interference conditions inside the cavity of the sensor [1]. The analog signals from sensor are transferred to both digital and analog values in the control unit and recorded with PC-based real-time data-acquisition hardware (●" Fig.2,●" Fig.3). We used the new probe in three patients with cirrhosis after gaining approval from our institutional review board. Portal– azygous disconnection was carried out after measurement of the variceal pressure, and portal vein pressure was measured (model 90308-11-14, Space Labs Inc., Issaquah, Washington, USA) in the initial stages of surgery by directly catheterizing the right gastroepiploic vein with a PE-16 catheter. The variceal and portal vein pressure recordings in the three patients were 22mmHg and 22.5mmHg, 18.5mmHg and 19mmHg, and 20mmHg and 20mmHg, respectively. Compared with conventional technology used to measure variceal pressure [2–5], it is much easier to place the new probe (diameter 2mm) into the correct position in relation to the varices through the endoscopic biopsy channel (●" Fig.4). We believe the new sensor can help determine variceal pressure in routine endoscopic examinations safely and effectively. Endoscopy_UCTN_Code_TTT_1AO_2AM

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of an Endoscopic Fibre-Optic Pressure Sensor for Noninvasive Measurement of Variceal Pressure

In this study, the authors have developed endoscopic fibre-optic pressure sensor to detect variceal pressure and presented the validation of in vivo and in vitro studies, because the HVPG requires catheterization of hepatic veins, which is invasive and inconvenient. Compared with HVPG, it is better to measure directly the variceal pressure without puncturing the varices in a noninvasive way.

متن کامل

Transcutaneous oxygen monitoring during fiberoptic bronchoscopy.

A transcutaneous oxygen sensor was used to detect the development of hypoxemia in patients undergoing fiberoptic bronchoscopy. Measurements of transcutaneous PO2 (tcPO2) correlated well with arterial PO2 (PaO2), and correctly detected all instances when PaO2 was less than 65 mm Hg. The sensor was noninvasive and caused no adverse effects.

متن کامل

Endoscopic variceal pressure measurements: response to isosorbide dinitrate.

An endoscopic pressure sensor has been evaluated in the measurement of oesophageal variceal pressure and its response to drug ingestion. The variceal pressure showed a highly significant correlation with the splenic pulp pressure (r = 0.97) in six patients with liver disease of diverse aetiology and with hepatic venous wedge pressure (r = 0.92) in eight alcoholic cirrhotic men. Intraduodenal in...

متن کامل

Comparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study

Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...

متن کامل

Noninvasive Blood Pressure Measurement Methods

This paper review the historical background of noninvasive blood pressure measurement methods with their accuracies achieved and explains the requirements for common national and international standards of accuracy. Also are shortly described the development of blood pressure measurement system and a method, named electronic palpation method (EP), suitable for the long-term measurement of heart...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Endoscopy

دوره 45 Suppl 2 UCTN  شماره 

صفحات  -

تاریخ انتشار 2013