The Clinical Experience of Computed Tomographic-Guided Navigation System in C1-2 Spine Instrumentation Surgery

نویسندگان

  • Sang-Uk Kim
  • Byoung-il Roh
  • Seong-Joon Kim
  • Sang-Don Kim
چکیده

OBJECTIVE To identify the accuracy and efficiency of the computed tomographic (CT)-based navigation system on upper cervical instrumentation, particularly C1 lateral mass and C2 pedicle screw fixation compared to previous reports. METHODS Between May 2005 and March 2014, 25 patients underwent upper cervical instrumentation via a CT-based navigation system. Seven patients were excluded, while 18 patients were involved. There were 13 males and five females; resulting in four degenerative cervical diseases and 14 trauma cases. A CT-based navigation system and lateral fluoroscopy were used during the screw instrumentation procedure. Among the 58 screws inserted as C1-2 screws fixation, their precise positions were evaluated by postoperative CT scans and classified into three categories : in-pedicle, non-critical breach, and critical breach. RESULTS Postoperatively, the precise positions of the C1-2 screws fixation were 81.1% (47/58), and 8.6% (5/58) were of non-critical breach, while 10.3% (6/58) were of critical breach. Most (5/6, 83.3%) of the critical breaches and all of non-critical breaches were observed in the C2 pedicle screws and there was only one case of a critical breach among the C1 lateral mass screws. There were three complications (two vertebral artery occlusions and a deep wound infection), but no postoperative instrument-related neurological deteriorations were seen, even in the critical breach cases. CONCLUSION Although CT-based navigation systems can result in a more precise procedure, there are still some problems at the upper cervical spine levels, where the anatomy is highly variable. Even though there were no catastrophic complications, more experience are needed for safer procedure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intra-operative Iso-C3D navigation for pedicle screw instrumentation of hangman's fracture: a case report.

Pedicle screw instrumentation of the upper cervical spine is rarely performed in trauma surgery because of the risk of damaging neurovascular structures. We report successful treatment of an unstable hangman's fracture with posterior pedicle screw fixation using Iso-C3D fluoroscopy-based computer navigation guidance. Postoperative computed tomographic images confirmed accurate placement of the ...

متن کامل

Anatomical and computed tomographic analysis of C1 vertebra.

Craniovertebral junction surgery requires knowledge regarding the anatomy of this region, particularly the C1 vertebra. Both C1 laminectomy and C1-2 instrumentation necessitate preoperative information about bony landmarks and the vertebral artery. This study compares the results obtained from anatomic and computed tomographic measurements of C1 bony landmarks. 31 C1 cervical vertebrae were mea...

متن کامل

Accuracy of image-guided pedicle screw placement using intraoperative computed tomography-based navigation with automated referencing. Part II: thoracolumbar spine.

BACKGROUND Image-guided spinal instrumentation may reduce complications in spinal instrumentation. OBJECTIVE To assess accuracy, time efficiency, and staff radiation exposure during thoracolumbar screw instrumentation guided by intraoperative computed tomography (iCT)-based neuronavigation (iCT-N). METHODS In 55 patients treated for idiopathic and degenerative deformities, 826 screws were i...

متن کامل

Current Navigation Modalities in Spine Surgery With a Focus on the Use of the O-arm in Deformity Surgery

2 Division of Orthopaedic Surgery, The Children’s Hospital of Philadelphia, Philadelphia, PA Image guidance in spine surgery has evolved from static modalities such as the plain radiograph to navigation systems such as the O-arm. Commonly used modalities include CT scan based navigation systems, 3D fluoroscopy, and most recently the O-arm. Each of these navigation systems improved on the capabi...

متن کامل

Computed Tomographic Anatomy and Topography of the Lower Respiratory System of the Southern White-Breasted Hedgehog (Erinaceus concolor)

Objective- The aim of this study was preparing detailed anatomic images of the thoracic cavity of the southern white-breasted hedgehog using the non-invasive computed tomography (CT) technique.Design- Descriptive study.Animals- Five southern white-breasted hedgehog (Erinaceus concolor) which is a species native to the Middle East, Anatolia, Transcaucasia, and Iran. Since some people...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 56  شماره 

صفحات  -

تاریخ انتشار 2014