Comparison of methods of enumerating coliforms after UV disinfection.

نویسندگان

  • R G Qualls
  • J C Chang
  • S F Ossoff
  • J D Johnson
چکیده

In view of the differences that have been found between the most-probable-number and membrane filtration methods for the recovery of coliforms from chlorinated samples, the survival of total and fecal coliforms in UV-irradiated effluent samples, as tested by the most-probable-number and standard single-step membrane filtration methods, was compared. There were no significant differences in the survival of total and fecal coliforms, as tested by the two methods. In a separate set of experiments comparing total and fecal coliform survival, as tested by the most-probable-number method, only a very small but statistically significant difference of 0.1 log survival units was found. For UV-disinfected wastewater effluents, standard one-step membrane filtration procedures are comparable to standard most-probable-number procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Effect of Perchlorine, Sodium Hypochlorite, and Electrochemical Method on Disinfection of Vegetables

Introduction: Many vegetables are eaten raw which can lead to the prevalence of food borne diseases if not properly sanitized. The aim of this study was to compare the effect of chlorine, bleach and multioxidant solution in disinfection of edible vegetables. Materials and Methods: In this experimental study, 100 g of vegetables (lettuce, basil and mint) was disinfected by sodium hypochlorite, ...

متن کامل

بررسی امکان گندزدایی پساب تصفیه خانه فاضلاب شمال اصفهان توسط سیستم های گندزدای کم فشار و فشار متوسط فرابنفش در مقیاس پایلوت

Backgrounds and Objectives:Today, due to health, environmental and economical problems, of chlorine application, UV radiation is better option than chlorine for disinfection of effluent. The aim of this study was disinfection of secondary effluent with UV radiation.Materials and Methods: Two types of UV disinfection system including low pressure (LP) and medium pressure (MP) was used to disinfe...

متن کامل

Influence of different combination modes of UV and NaClO on disinfecting effect of hospital sewage

Combined disinfection with UV radiation and sodium hypochlorite was applied in disinfection the effluent after secondary treatment of hospital sewage. The inactivation effect of different combination modes and sequences of UV and sodium hypochlorite was studied. The contrast experiments of disinfection effect and the levels of residual chlorine were conducted by adding different dosage of sodiu...

متن کامل

Improved wastewater disinfection by ultrasonic pre-treatment.

The objective of our work is to evaluate the scientific and economic potential of US application as a pre-treatment step in combination with UV to optimise the disinfection process of wastewaters. Ultrasound application of 20 s at low density of 30 W/l changed the particle size distribution (PSD) of the samples, the mean particle diameter dropped from 70 to 11 microm. Generally it is assumed th...

متن کامل

Comparison of ultraviolet light emitting diodes with traditional UV for greywater disinfection

The current technological status of ultraviolet light emitting diodes (UV-LEDs) has reached a point where small-scale ultraviolet (UV) water disinfection applications, that is, for greywater reuse appear increasingly promising. This study compares the germicidal and economical aspects of UV-LEDs with traditional UV. Pure cultures and environmental greywater samples were exposed to different rad...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied and environmental microbiology

دوره 48 4  شماره 

صفحات  -

تاریخ انتشار 1984