Left ventricular mechanical activity detected by impedance recording

نویسندگان

  • Milos Taborsky
  • Jindrich Kupec
  • Roman Vopalka
  • Alberto Barbetta
  • Franco Di Gregorio
چکیده

AIMS Recording and analysing impedance fluctuation along the cardiac cycle in the right (RV) and left ventricles (LV). METHODS AND RESULTS During a biventricular (BiV) implantation procedure, impedance was sequentially derived between the atrial ring electrode and either electrode (tip or ring) of the RV lead [transvalvular impedance (TVI)], and between the atrial ring and either the tip or ring electrode of a coronary sinus lead, positioned in a cardiac vein [left ventricle impedance (LVI)]. The LVI signal was also recorded by the implanted pacemaker at the 1 day and 3 months follow-ups. With intrinsic conduction, TVI showed an average increase of 53 +/- 29 ohm during ventricular systole, whereas at the same time, LVI decreased by 45 +/- 21 ohm (25 and 23 patients, respectively, out of 28 tested cases). Transvalvular impedance and LVI displayed a similar time course, which appeared to be related to the systolic timing in the RV and LV. Both LVI amplitude and duration decreased as a function of the cardiac rate. The LVI deflection started immediately after LV stimulation, and often anticipated the R-wave sensing after contralateral pacing. At the 3-month follow-up, LVI amplitude was decreased in 70% of cases and increased in the remainder, with a non-significant average change of -5 +/- 85% with respect to the acute recordings. CONCLUSION Transvalvular impedance properties are consistent with the assumption of an inverse relationship with RV volume. Though LVI requires a different physical interpretation, the waveform duration might reflect the timing of LV myocardial contraction. In this hypothesis, the relationship between TVI and LVI could provide insight into the effects of BiV pacing on mechanical synchronization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Physiological loading of isolated feline cardiac muscle. The interaction between muscle contraction and vascular impedance in the production of pressure and flow waves.

Isolated cat papillary muscle preparations were assumed to contract in the wall of a hypothetical cylindrical model of the left ventricle ejecting into a vascular impedance. Using analogcomputing techniques, a feedback system was created between shortening, velocity of shortening, and the load on the muscle. This feedback function could be modulated by altering the resistance and capacitance co...

متن کامل

Impact of Acute Changes of Left Ventricular Contractility on the Transvalvular Impedance: Validation Study by Pressure-Volume Loop Analysis in Healthy Pigs

BACKGROUND The real-time and continuous assessment of left ventricular (LV) myocardial contractility through an implanted device is a clinically relevant goal. Transvalvular impedance (TVI) is an impedentiometric signal detected in the right cardiac chambers that changes during stroke volume fluctuations in patients. However, the relationship between TVI signals and LV contractility has not bee...

متن کامل

Instantaneous measurement of left and right ventricular stroke volume and pressure-volume relationships with an impedance catheter.

The feasibility of using continuous on-line recording of intraventricular electrical impedance to measure ventricular stroke volume was assessed in 12 patients at cardiac catheterization with a multielectrode impedance catheter and a 1.3 kHz measuring current of 4 microA. Stroke volumes determined by electrical impedance were compared with stroke volumes determined by the thermodilution techniq...

متن کامل

Diagnostic Methods - Hemodynamics and Ventricular Function

The feasibility of using continuous on-line recording of intraventricular electrical impedance to measure ventricular stroke volume was assessed in 12 patients at cardiac catheterization with a multielectrode impedance catheter and a 1.3 kHz measuring current of 4 ,A. Stroke volumes determined by electrical impedance were compared with stroke volumes determined by the thermodilution technique i...

متن کامل

Hemodynamics and Ventricular Function

The feasibility of using continuous on-line recording of intraventricular electrical impedance to measure ventricular stroke volume was assessed in 12 patients at cardiac catheterization with a multielectrode impedance catheter and a 1.3 kHz measuring current of 4 ,A. Stroke volumes determined by electrical impedance were compared with stroke volumes determined by the thermodilution technique i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2010