The Relationship between Temporal Changes in Proximal Neck Angulation and Stent-Graft Migration after Endovascular Abdominal Aortic Aneurysm Repair.
نویسندگان
چکیده
BACKGROUND In recent years, endovascular abdominal aortic aneurysm repair (EVAR) for treating abdominal aortic aneurysms (AAA) has become quite prevalent in Japan. Though little information is available about temporal changes in proximal neck angulation due to the difficulties encountered in measuring the angle. Therefore, we examined temporal changes in proximal neck angulation and its relationship to stent-graft migration after EVAR. METHODS Between June 2007 and March 2010, 159 patients underwent EVAR for treatment of fusiform AAAs at our hospital. This study focuses on the 80 patients among this group whose treatment sites and subsequent stent grafts were examined by contrast computed tomographic angiography before surgery, directly after surgery (within 4 days), as well as 1 year and 2 years thereafter. We created curved planar reconstruction (CPR) images and measured the length of migration and neck angle using our method. RESULTS At 2 years after EVAR, the average length of proximal landing zone was 21.4 ± 9.2 mm. The average length of stent migration after 2 years was 1.41 ± 2.68 mm. The average neck angle was 33.9° preoperatively and 29.9° directly after surgery yielding a significant difference. However, 1 and 2 years after surgery the average neck angle was 28.2° and 28.4°, respectively. The number of patients experiencing a change >6° in the angle of the proximal neck between the preoperative condition and that directly after surgery was 16 (34.8%) with the use of Zenith stent grafts (n = 46) and 14 (41.2%) with the use of Excluder stent grafts (n = 34). There was no correlation between the proximal neck angle and migration of the proximal stent graft. In addition, there was no correlation between the changes in proximal neck angle and the secondary intervention rate and the occurrence of endoleak. CONCLUSIONS There was a significant change in the neck angle between the preoperative condition and the immediate postoperative condition. However, there was no clear relationship found between the angle of the neck and the proximal stent-graft migration. Postoperative changes in the proximal neck angle just after EVAR and subsequent temporal changes during a 2-year follow-up period do not appear to predict stent-graft migration, secondary intervention rates, or the occurrence of endoleak.
منابع مشابه
Prevention of Kinked Stent Graft Limb Due to Severe Angulated Proximal Neck during Endovascular Repair for Abdominal Aortic Aneurysm.
Although the technology of endovascular aortic repair (EVAR) for abdominal aortic aneurysm (AAA) is evolving that make it appealing for challenging anatomy, proximal aortic neck morphology, especially severe angulation, is still one of the most determinants for a successful procedure. We describe a patient of AAA with severely angulated proximal neck, in whom kinked stent graft limb occurred ag...
متن کاملThrombotic Occlusion of Stent Graft Limbs due to Severe Angulation of Aortic Neck in Endovascular Repair of Abdominal Aortic Aneurysm
Endovascular aneurysm repair (EVAR) is a safe alternative to open surgical repair for an abdominal aortic aneurysm. However, unfavorable aortic anatomy of the aneurysm has restricted the widespread use of EVAR. Anatomic limitation is most often related to characteristics of the proximal neck anatomy. In this report, we described a patient with a severely angulated proximal neck who underwent EV...
متن کاملA computational study of the magnitude and direction of migration forces in patient-specific abdominal aortic aneurysm stent-grafts.
OBJECTIVES Endovascular aneurysm repair for abdominal aortic aneurysm (AAA) is now a widely adopted treatment. Several complications remain to be fully resolved and perhaps the most significant of these is graft migration. Haemodynamic drag forces are believed to be partly responsible for migration of the device. The objective of this work was to investigate the drag forces in patient-specific ...
متن کاملThe advantages of Aorfix for endovascular repair of abdominal aortic aneurysm.
AIM The aim of this paper was to review the use of the Aorfix stent-graft in the endovascular repair of abdominal aortic aneurysms and to report the early results of a multicenter study conducted on patients receiving this endograft. METHODS A retrospective review of 40 patients having the Aorfix stent-grafts for their aneurysm repair was undertaken at two centers. Patient notes and imaging f...
متن کاملEndovascular repair of abdominal aortic aneurysms with reverse taper neck anatomy using the Endurant stent-graft: analysis of stent-graft oversizing.
PURPOSE To evaluate endovascular repair of infrarenal abdominal aortic aneurysms (AAA) using the Endurant stent-graft and compare the outcomes of patients with different neck anatomies, particularly as pertains to stent-graft oversizing. METHODS A retrospective review was conducted of 75 consecutive patients (69 men; mean age 75 years) undergoing endovascular AAA repair using the Endurant Ste...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Annals of vascular surgery
دوره 39 شماره
صفحات -
تاریخ انتشار 2017